Distributed feeder automation (FA) needs to automatically recognize the changes in the feeder topology in real-time and has to configure the application topology of the corresponding distributed functions. This paper analyzes the application topology's requirements when implementing distributed FA for the feeder equipped with a smart terminal unit (STU) and a fault passage indicator (FPI). Based on IEC 61850, the functional logic node and topology configuration of intelligent electronic devices (IEDs) are studied. The application topology identification and data flow dynamic binding methods for fault location, fault isolation, and power supply restoration are proposed. A case study verifies the effectiveness of the proposed method.
机译:分布式馈线自动化(FA)需要实时自动识别馈线拓扑的变化,并配置相应分布式功能的应用拓扑。本文分析了为配备智能终端单元(STU)和故障通道指示器(FPI)的馈线实现分布式FA时的应用拓扑要求。基于IEC 61850,研究了智能电子设备(IED)的功能逻辑节点和拓扑结构。提出了故障定位、故障隔离和电源恢复的应用拓扑识别和数据流动态绑定方法。算例验证了所提方法的有效性。