首页> 外文期刊>Aviation, space, and environmental medicine. >Pressure breathing without a counter-pressure vest does not impair acceleration tolerance up to 9 G.
【24h】

Pressure breathing without a counter-pressure vest does not impair acceleration tolerance up to 9 G.

机译:没有背压背心的压力呼吸不会损害高达9 G的加速度公差。

获取原文
获取原文并翻译 | 示例
           

摘要

INTRODUCTION: This study was to determine whether safe and adequate G-protection by pressure breathing during G (PBG) could be maintained if the COMBAT EDGE counter-pressure vest were eliminated to ensure aircrew do not unnecessarily endure a possible in-flight discomfort or distraction. METHODS: Centrifuge exposures up to +9 Gz were completed by 11 subjects, including 5 F-15 aircrew, using PBG at 60 mmHg pressure with and without the counter-pressure vest. Additional G-exposures using pressures of 0, 30, and 45 mmHg were performed without the vest. RESULTS: Elimination of the COMBAT EDGE counter-pressure vest did not significantly reduce G-tolerance. During gradual onset G exposure, the mean G level reached with PBG was 8.4 G without the vest and 8.2 G with the vest. In comparison, 6.7 G was reached without PBG. Mean times at G with rapid onset G exposure were 59 and 60 s, respectively, compared with 49 s without PBG. PBG, with or without the vest, was preferred by all test subjects. PBG at 60 mmHg produced the highest G protection and was preferred by the test subjects over lesser pressures. Subjects reported no adverse effects from the use of PBG without chest counter-pressure. CONCLUSION: The use of PBG and the anti-G straining manuever (AGSM) together enhances G tolerance and comfort more than AGSM alone. Elimination of the counter-pressure vest during use of PBG does not hinder an individual's ability to reach +9 Gz or complete a short duration simulated aerial combat maneuver G exposure. Further research is needed to determine if use of PBG without chest counter-pressure increases fatigue during multiple sorties or produces other aeromedical problems in operational environments.
机译:简介:本研究旨在确定,如果消除COMBAT EDGE背压背心以确保机组人员不必不必要地承受飞行中的不适或分散注意力,在G(PBG)期间通过压力呼吸(PBG)是否可以维持安全和充分的G保护作用。方法:在60 mmHg的压力下使用PBG(有或没有反压背心),由11位受试者(包括5名F-15空勤人员)完成了高达+9 Gz的离心暴露。在没有背心的情况下,使用0、30和45 mmHg的压力进行了额外的G暴露。结果:消除COMBAT EDGE背压背心并没有显着降低G耐受性。在逐渐发作G期间,PBG在没有背心的情况下达到的平均G水平为8.4 G,在背心情况下达到8.2G。相比之下,不使用PBG则达到6.7G。与没有PBG的49 s相比,发生G快速发作的G的平均时间分别为59 s和60 s。有或没有背心的PBG都是所有测试对象的首选。在60 mmHg的PBG产生最高的G保护作用,并且比较小的压力更受测试对象的青睐。受试者报告在没有胸部反压的情况下使用PBG不会产生不良影响。结论:与单独使用AGSM相比,PBG和抗G应变操纵器(AGSM)的结合使用可提高G耐受性和舒适性。在使用PBG期间消除反压背心不会影响个人达到+9 Gz的能力或完成短期的模拟空战演习G暴露的能力。需要进行进一步的研究以确定在没有胸部反压的情况下使用PBG是否会增加多次飞行时的疲劳度或在操作环境中产生其他航空医学问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号