Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver Comparison to Conventional Free-Breathing Turbo Spin Echo

机译:Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver Comparison to Conventional Free-Breathing Turbo Spin Echo

获取原文
获取原文并翻译 | 示例

摘要

ObjectivesThe aim of this study was to evaluate the usefulness of breath-hold turbo spin echo with deep learning-based reconstruction (BH-DL-TSE) in acquiring fat-suppressed T2-weighted images (FS-T2WI) of the liver by comparing this method with conventional free-breathing turbo spin echo (FB-TSE) and breath-hold half Fourier single-shot turbo spin echo with deep learning-based reconstruction (BH-DL-HASTE).Materials and MethodsThe study cohort comprised 111 patients with suspected liver disease who underwent 3 T magnetic resonance imaging. Fifty-eight focal solid liver lesions >= 10 mm were also evaluated. Three sets of FS-T2WI were acquired using FB-TSE, prototypical BH-DL-TSE, and prototypical BH-DL-HASTE, respectively. In the qualitative analysis, 2 radiologists evaluated the image quality using a 5-point scale. In the quantitative analysis, we calculated the lesion-to-liver signal intensity ratio (LEL-SIR). Friedman test and Dunn multiple comparison test were performed to assess differences among 3 types of FS-T2WI with respect to image quality and LEL-SIR.ResultsThe mean acquisition time was 4 minutes and 43 seconds +/- 1 minute and 21 seconds (95 confidence interval, 4 minutes and 28 seconds to 4 minutes and 58 seconds) for FB-TSE, 40 seconds for BH-DL-TSE, and 20 seconds for BH-DL-HASTE. In the qualitative analysis, BH-DL-HASTE resulted in the fewest respiratory motion artifacts (P < 0.0001). BH-DL-TSE and FB-TSE exhibited significantly less motion-related signal loss and clearer intrahepatic vessels than BH-DL-HASTE (P < 0.0001). Regarding the edge sharpness of the left lobe, BH-DL-HASTE scored the highest (P < 0.0001), and BH-DL-TSE scored higher than FB-TSE (P = 0.0290). There were no significant differences among 3 types of FS-T2WI with respect to the edge sharpness of the right lobe (P = 0.1290), lesion conspicuity (P = 0.5292), and LEL-SIR (P = 0.6026).ConclusionsBH-DL-TSE provides a shorter acquisition time and comparable or better image quality than FB-TSE, and could replace FB-TSE in acquiring FS-T2WI of the liver. BH-DL-TSE and BH-DL-HASTE have their own advantages and may be used complementarily.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号