首页> 外文期刊>Pathology >Lack of standardisation in interpretation and reporting of autoantibody assays: a survey analysis of Australasian laboratories with focus on line immunoassays
【24h】

Lack of standardisation in interpretation and reporting of autoantibody assays: a survey analysis of Australasian laboratories with focus on line immunoassays

机译:Lack of standardisation in interpretation and reporting of autoantibody assays: a survey analysis of Australasian laboratories with focus on line immunoassays

获取原文
获取原文并翻译 | 示例
       

摘要

Autoantibody assays are reported in a variety of formats. Results only slightly above established cut-offs provide lower likelihood ratios; therefore, their clinical significance may be more uncertain, which is not readily communicated with dichotomous qualitative reporting. Line immunoassays (LIA) are a common method for detecting antibodies to extractable nuclear antigens (ENA) and myositis-associated antibodies. However, recom-mended positive cut-offs are contentious. We distributed a survey via e-mail to participants in the Royal College of Pathologists of Australasia Quality Assurance Program (RCPAQAP) Immunology modules and to a dedicated immunology mailing list in Australasia. Questions explored general viewpoints surrounding auto -antibody reporting, as well as current laboratory practices, with particular focus on interpretation and reporting of the most commonly used ENA LIA manufactured by Euroimmun. There were 31 responders, representative of at least 17 unique laboratories across Australia (8 public, 5 private) and New Zealand (4 laboratories). Responses suggest that autoantibody reporting is not standardised; there was variation in general viewpoints and reporting practices, particularly regarding the interpretation of and positive cut-offs used for the Euroimmun ENA LIA, which were con-trary to the manufacturer's guidelines in a majority of the responses. Interpretative qualitative reporting based on results from other investigations and the clinical history was a common theme. There is large variation in the reporting of autoantibody assays within Australasia, especially by LIA. A majority of respondents report the most commonly used ENA LIA contrary to manufacturer's guidelines; alternative positive cut-offs are commonly utilised. LIA reports should indicate the level of positivity to enhance their relevance in the clinical decision-making process.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号