...
首页> 外文期刊>Building and environment >Overall uncertainty analysis of zonal indoor air temperature measurement in an in-use office building
【24h】

Overall uncertainty analysis of zonal indoor air temperature measurement in an in-use office building

机译:Overall uncertainty analysis of zonal indoor air temperature measurement in an in-use office building

获取原文
获取原文并翻译 | 示例
           

摘要

? 2022 The AuthorsGenerally, studies where the zonal indoor air temperature is measured only consider the manufacturers' sensor accuracy to determine the overall Temperature Uncertainty (UT), without considering other sources of uncertainties that affect the indoor air temperature measurement of a thermal zone within a building. Thus, in this research, the definition and estimation method of the overall Temperature Uncertainty (UT) has been developed, together with a decoupling method to obtain the Temperature's Spatial Uncertainty (UTSP), in which all causes of uncertainty regarding the temperature measurement are included, except the Temperature Sensor Uncertainty (UTS). Using the measurements of the indoor air temperature from sensors installed randomly in four offices of an in-use tertiary building, the developed statistical analysis has been applied to estimate and decouple the overall indoor air Temperature Uncertainty (UT) of each monitored office. Each studied thermal zone represents a different office typology composed of divisions with different volumes that allow their classification. The first study carried out was the estimation of the experimental accuracy by estimating the Temperature Sensor Uncertainty (UTS), including both the sensor uncertainty plus the monitoring system uncertainty in this value. This first study has allowed us to discover the importance of the estimation of the Temperature Sensor Uncertainty (UTS) when installing a monitoring system, inasmuch as the experimental accuracy could be different from the manufacturer's accuracy, as reflected in the results of this research. Secondly, based on the developed statistical method, for each of the monitored thermal zones, the overall zonal indoor air Temperature Uncertainty (UT) is estimated in order to finally decouple it into the Temperature Sensor Uncertainty (UTS) and Temperature's Spatial Uncertainty (UTSP). The decoupling results show that, depending on the office typology, the percentage weight of the Temperature Sensor Uncertainty (UTS) only represents between 5% and 11% of the overall zonal indoor air Temperature Uncertainty (UT).

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号