Comparing the accuracy of three-dimensional mini-optical portable navigation and accelerometer-based portable navigation system for acetabular cup placement during total hip arthroplasty

机译:Comparing the accuracy of three-dimensional mini-optical portable navigation and accelerometer-based portable navigation system for acetabular cup placement during total hip arthroplasty

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Introduction This study compared the accuracy of three dimensional (3D) mini-optical navigation and accelerometer-based portable navigation systems for cup positioning during a total hip arthroplasty (THA) in the supine position. Materials and methods This retrospective cohort study assessed data for 77 hips using 3D mini-optical navigation (n = 37) and accelerometer-based portable navigation (n = 40). The patients underwent THA through the mini-anterolateral approach in the supine position using a portable navigation system. We assessed the preoperative target angles, recorded intraoperative cup angles, postoperative CT imaging angles, cup angle measurement errors, and other clinical parameters. Results The mean absolute differences in radiographic inclination were similar between 3D mini-optical navigation and accelerometer-based portable navigation systems during THA in the supine position (2.8 degrees +/- 1.7 degrees vs 2.8 degrees +/- 1.9 degrees, p = 0.637). The mean absolute differences in radiographic anteversion were also similar (2.6 degrees +/- 2.3 degrees vs 2.5 degrees +/- 1.9 degrees, p = 0.737). Cup malalignment (absolute difference of inclination or anteversion between postoperative CT and preoperative target angle of > 5 degrees) was significantly associated with body mass index (BMI) in accelerometer-based portable navigation but not in 3D mini-optical navigation. Conclusions This is the first study to compare the accuracy of cup positioning between 3D mini-optical and accelerometer-based navigations in THA in the supine position. Both portable navigation systems accurately identified the orientation of cup placement. The accuracy of 3D mini-optical navigation is not affected by high BMI and may be preferred over other options in such patients.
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号