...
首页> 外文期刊>hydrology and earth system sciences >Technical note: Introduction of a superconducting gravimeter as novel hydrological sensor for the Alpine research catchment Zugspitze
【24h】

Technical note: Introduction of a superconducting gravimeter as novel hydrological sensor for the Alpine research catchment Zugspitze

机译:Technical note: Introduction of a superconducting gravimeter as novel hydrological sensor for the Alpine research catchment Zugspitze

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

GFZ (German Research Centre for Geosciences) set up the Zugspitze Geodynamic Observatory Germany with a worldwide unique installation of a superconducting gravimeter at the summit of Mount Zugspitze on top of the Partnach spring catchment. This high alpine catchment is well instrumented, acts as natural lysimeter and has significant importance for water supply to its forelands, with a large mean annual precipitation of 2080 mm and a long seasonal snow cover period of 9 months, while showing a high sensitivity to climate change. However, regarding the majority of alpine regions worldwide, there is only limited knowledge on temporal water storage variations due to sparsely distributed hydrological and meteorological sensors and the large variability and complexity of signals in alpine terrain. This underlines the importance of well-equipped areas such as Mount Zugspitze serving as natural test laboratories for improved monitoring, understanding and prediction of alpine hydrological processes. The observatory superconducting gravimeter, OSG 052, supplements the existing sensor network as a novel hydrological sensor system for the direct observation of the integral gravity effect of total water storage variations in the alpine research catchment at Zugspitze. Besides the experimental set-up and the available data sets, the gravimetric methods and gravity residuals are presented based on the first 27 months of observations from 29 December 2018 to 31 March 2021. The snowpack is identified as being a primary contributor to seasonal water storage variations and, thus, to the gravity residuals with a signal range of up to 750  nm s −2 corresponding to 1957 mm snow water equivalent measured with a snow scale at an altitude of 2420 m at the end of May 2019. Hydro-gravimetric sensitivity analysis reveal a snow–gravimetric footprint of up to 4 km distance around the gravimeter, with a dominant gravity contribution from the snowpack in the Partnach spring catchment. This shows that the hydro-gravimetric approach delivers representative integral insights into the water balance of this high alpine site.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号