首页> 外文期刊>experimental heat transfer >GLOBAL PERFORMANCE OF A PROTOTYPE BRAZED PLATE HEAT EXCHANGER IN A LARGE REYNOLDS NUMBER RANGE
【24h】

GLOBAL PERFORMANCE OF A PROTOTYPE BRAZED PLATE HEAT EXCHANGER IN A LARGE REYNOLDS NUMBER RANGE

机译:GLOBAL PERFORMANCE OF A PROTOTYPE BRAZED PLATE HEAT EXCHANGER IN A LARGE REYNOLDS NUMBER RANGE

获取原文
       

摘要

Investigations were conducted with brazed plate heat exchangers and consisted of defining the thermal and hydrodynamic performances of these types of heat exchanger and comparing them in terms of the hydraulic diameter parameter. The hydrodynamic characteristics are presented in the turbulent and laminar-transitional flow regions. An equation of a type a Rebhas been used to accurately fit the isothermal pressure drop data in both the viscous and turbulent flow regions. A distinctive kink of the hydrodynamic characteristics occurred at a critical Reynolds number indicating the start of the turbulent flow regime. Moreover, in the turbulent part of flow, two linear zones can also be defined, and at the junction between them, some flow disturbances have been measured due mainly to the flow change between the quasi- and fully turbulent flow regimes. Thermal investigations were also conducted with regard to the hydraulic diameter parameter, and the thermal and hydrodynamic correlations are then coupled by only one equation predicting the global performance.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有