RESEARCH AND EDUCATION Analysis of the influence of the facial scanning method on the transfer accuracy of a maxillary digital scan to a 3D face scan for a virtual facebow technique: An in vitro study

机译:研究与教育 面部扫描方法对上颌骨数字扫描向虚拟面部弓技术的 3D 面部扫描转移精度的影响分析:一项体外研究

获取原文
获取原文并翻译 | 示例

摘要

Statement of problem. With the emergence of virtual articulators, virtual facebow techniques have been developed for mounting maxillary digital scans to virtual articulators. Different scanning methods can be used to obtain 3D face scans, but the influence that these methods have on the accuracy with which a maxillary digital scan is transferred to a 3D face scan is unknown. Purpose. The purpose of this in vitro study was to analyze the influence of the facial scanning method on the accuracy with which a maxillary digital scan is transferred to a 3D face scan in a virtual facebow technique. Material and methods. According to a virtual facebow technique, a maxillary digital scan was transferred to a standard virtual patient -who had the maxillary digital scan in its real location -guided by an intraoral transfer element by using different 3D face scans with the intraoral transfer element in place (reference 3D face scans) obtained with 2 different scanning methods: 10 obtained with an accurate scanning method based on structured white light technology and 10 obtained with a less accurate scanning method based on structure-from-motion technology. For each situation, deviation between the maxillary digital scan at the location obtained via the virtual facebow technique and at its real location was obtained in terms of distance by using a novel methodology. From these distances, the accuracy was assessed in terms of trueness and precision, according to the International Organization for Standardization (ISO) 5725-1. The Student t test with Welch correction was used to determine if the accuracy with which the maxillary digital scan was transferred to the standard virtual patient was influenced by the facial scanning method used to obtain the reference 3D face scans (a=.05). Results. Significant differences (P<.05) were found among the trueness values obtained when using the different facial scanning methods, with a very large effect size. A trueness of 0.138 mm and a precision of 0.022 mm were obtained by using the structured white light scanning method, and a trueness of 0.416 mm and a precision of 0.095 mm were acquired when using the structure-from-motion scanning method. Conclusions. The accuracy with which a maxillary digital scan is located with respect to a 3D face scan in a virtual facebow technique is strongly influenced by the facial scanning method used. (J Prosthet Dent 2022;128:1024-31)
机译:问题陈述。随着虚拟咬合架的出现,已经开发了用于将上颌数字扫描安装到虚拟咬合架上的虚拟面弓技术。可以使用不同的扫描方法来获得 3D 面部扫描,但这些方法对将上颌数字扫描转移到 3D 面部扫描的准确性的影响尚不清楚。目的。这项体外研究的目的是分析面部扫描方法对在虚拟面部弓技术中将上颌数字扫描转移到 3D 面部扫描的准确性的影响。材料和方法。根据虚拟面弓技术,将上颌骨数字扫描转移到标准虚拟患者身上 - 该患者在其真实位置进行了上颌数字扫描 - 通过使用不同的 3D 面部扫描和口内转移元件(参考 3D 面部扫描)获得 2 种不同的扫描方法获得: 10 使用基于结构白光技术的精确扫描方法获得,10 使用基于结构运动技术的不太精确的扫描方法获得。对于每种情况,通过使用一种新颖的方法,在通过虚拟面弓技术获得的位置与其真实位置的上颌数字扫描之间的偏差在距离方面。根据国际标准化组织 (ISO) 5725-1 的规定,从这些距离评估准确性的真实性和精度。使用 Welch 校正的学生 t 检验来确定将上颌数字扫描转移到标准虚拟患者的准确性是否受到用于获得参考 3D 面部扫描的面部扫描方法的影响 (a=.05)。结果。使用不同的面部扫描方法获得的真实度值之间存在显著差异(P<.05),且效应量非常大。采用结构白光扫描法获得的正确度为0.138 mm,精度为0.022 mm,采用运动结构扫描法的正确度为0.416 mm,精度为0.095 mm。结论。在虚拟面部弓技术中,上颌数字扫描相对于 3D 面部扫描的定位精度受到所用面部扫描方法的强烈影响。(J 假肢凹痕 2022;128:1024-31)

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号