...
首页> 外文期刊>journal of diabetes and metabolic disorders >Mass spectrometry with derivatization method for concurrent measurement of amino acids and acylcarnitines in plasma of diabetic type 2 patients with diabetic nephropathy
【24h】

Mass spectrometry with derivatization method for concurrent measurement of amino acids and acylcarnitines in plasma of diabetic type 2 patients with diabetic nephropathy

机译:Mass spectrometry with derivatization method for concurrent measurement of amino acids and acylcarnitines in plasma of diabetic type 2 patients with diabetic nephropathy

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BackgroundAmino acids (AAs) and acylcarnitines play a key role in metabolic disease and can be used as biomarkers of various diseases such as malignancies, type 2 diabetes (T2D), insulin resistance, and cardiovascular diseases, therefore, designing an accurate and simple laboratory method that simultaneously measure both groups of substances, could improve the process of analytes quantification. In this research, a flow injection tandem mass spectrometry (FI-MS/MS) method for simultaneous measurement of AAs and acylcarnitines in addition to results of validation is explained.MethodsSamples were mixed with internal standards and after derivatization (with butanolic-HCL), AAs, and acylcarnitines were quantified by tandem mass spectrometry (SCIEX API 3200) . Analytical performance studies were designed based on the Clinical and Laboratory Standards Institute (CLSI) guidelines including precision, accuracy, linearity, and limit of detection-quantification (LOD-LOQ) experiments. Samples from patients with T2D in different stages of kidney disease were also analyzed to ensure the clinical usage of the method.ResultsPerformance evaluation of the method demonstrated adequate results. The mean of estimated inter-assay precision (reported as a coefficient variation) for AAs and acylcarnitines were less than 8.7% and 12.3%, the estimated mean bias was below 8.8% and 10.2% respectively. LOD of analytes ranged between 0.6–10 μmol per liter (μmol/L) for AAs and 0.02-1 μmol/L for acylcarnitines. LOQ analytes showed a range of 2–25 μmol/L and 0.05–5 μmol/L for AAs and carnitine/acylcarnitines respectively. In diabetic patients sample analysis, a significant increase in acylcarnitines (C2, C4, C5DC, C6, C8, C10, C14) and citrulline with a significant decrease in valine were seen in patients with severely increased albuminuria.ConclusionFI-MS/MS method with pre-injection derivatization with butanolic-HCL can be used for concurrent measurement of AAs and carnitine/acylcarnitines in a short time and it satisfies the analytical performance requirements. This method is applied for AAs and carnitine/acylcarnitines measurement in patient with T2DM and results show some of the acylcarnitines and AAs can be involved in diabetic nephropathy development.

著录项

  • 来源
    《journal of diabetes and metabolic disorders》 |2021年第1期|591-599|共9页
  • 作者单位

    Department of mechanical engineering, University of Bristol;

    Metabolomics and genomics research center, Endocrinology and metabolism molecular-cellular sciences institute, Tehran University of medical sciences;

    Department of Clinical Biochemistry, School of Medicine, Tehran University of Medical SciencesCell Therapy and Regenerative Medicine Research Center, Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical SciencesMetabolic Disorders Research Center, Endocrinology and Metabolism Molecular -Cellular Sciences Institute, Tehran University of Medical SciencesEndocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical SciencesDiabetes Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 英语
  • 中图分类
  • 关键词

    Amino acid; Carnitine; Acylcarnitine; Tandem mass spectrometry; Diabetes; Nephropathy;

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号