Abstract To overcome the shortcomings of traditional shear walls, structure systems have been proposed and investigated. One such structure system is a steel-reinforced concrete shear wall, which has certain desirable properties such as good load-bearing capacity, stiffness, and seismic performance. This paper proposes an M-section cold-formed thin-walled steel reinforced concrete (MCTSR) shear wall, which uses M-section cold-formed thin-walled steel to function as reinforcements. Six specimens with different permanent formwork types, axial compression ratios, reinforcement diameters, and other parameters were tested under cyclic loading to investigate seismic performance. The results demonstrate that various types of permanent formwork, including cement fibrolite plate, metal lathing, and polystyrene board can meet the requirement of related seismic design codes, construction demand, and assembly requirements, and have no obvious impact on the ultimate load-bearing capacity, lateral stiffness, and stiffness degradation rate. However, it changes the energy dissipation capacity and ductility, which are two important indexes to evaluate seismic performance in engineering practice. The failure mechanism and the influence of axial compression ratio, reinforcement diameter, and space between reinforcements are discussed. The shear-strength equations proposed by various countries’ or regions’ codes were analyzed, which can be used as a reference for related engineers and designers. Finite-element models for MCTSR shear walls were established for further investigation.
机译:摘要 针对传统剪力墙的缺点,提出并研究了传统剪力墙的结构体系。其中一种结构体系是钢筋混凝土剪力墙,它具有一定的理想性能,例如良好的承载能力、刚度和抗震性能。本文提出了一种M型冷弯型薄壁钢筋混凝土(MCTSR)剪力墙,该剪力墙采用M型冷弯型薄壁钢作为钢筋。在循环荷载作用下,对6个不同永久模板类型、轴压比、钢筋直径等参数的试件进行了抗震性能试验。结果表明,水泥纤维板、金属板条、聚苯板等各类永久性模板均能满足相关抗震设计规范、施工要求和装配要求,对极限承载力、侧向刚度、刚度退化率无明显影响。然而,它改变了耗能能力和延性,这是工程实践中评价抗震性能的两个重要指标。讨论了破坏机理以及轴压比、钢筋直径和钢筋间距的影响。分析了各国或地区规范提出的抗剪强度方程,可为相关工程师和设计人员提供参考。建立了MCTSR剪力墙的有限元模型,以供进一步研究。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号