首页> 外文期刊>Journal of Structural Engineering >Behavior of CFST Column to Concrete-Filled U-Shaped Steel Beam Joints with Slabs under Cyclic Loading
【24h】

Behavior of CFST Column to Concrete-Filled U-Shaped Steel Beam Joints with Slabs under Cyclic Loading

机译:循环荷载作用下钢管混凝土柱对混凝土填充U型钢梁节点和板的行为

获取原文
获取原文并翻译 | 示例

摘要

This study proposes a through-beam composite joint system to connect square concrete-filled steel tubular (CFST) columns and concrete-filled U-shaped steel (CFUS) beams. In the joint system, channel-shaped holes in the square steel tube allow direct load transfer of the beam. Two procedures for constructing the joints, denoting two types of joint details (i.e., Type-I and Type-II), are proposed to facilitate field installation. Six cruciform joints were tested under combined constant axial compression and cyclic lateral loading. Three Type-I joints were tested. The main test parameters were the loading procedure and the axial load ratio applied on the CFST column. All Type-I specimens reached their beam flexural capacities followed by the fracture of fillet welds at beam ends, as well as the fracture of the reduced steel section within the joint zone. Three Type-II joints were constructed with the same column and beam section dimensions as the Type-I specimens. The main test parameters were the additional flexural rebars at beam ends and the axial load ratio. All Type-II specimens reached their beam flexural capacities, followed by the fracture of the heat-affected zone at beam ends. All specimens failed in a ductile manner, had favorable hysteretic performance, and complied with the acceptance criteria. Design considerations are proposed based on the test and analysis results.
机译:本研究提出了一种连接方形混凝土填充钢管(CFST)柱和混凝土填充U型钢(CFUS)梁的通梁组合节点系统。在节点系统中,方形钢管上的槽形孔允许梁的直接荷载传递。提出了两种接头构造程序,表示两种类型的接头细节(即 I 型和 II 型),以方便现场安装。在恒定轴压和循环侧向载荷的组合下测试了6个十字形接头。测试了三个 I 型关节。主要试验参数是加载程序和施加在钢管混凝土柱上的轴向载荷比。所有I型试件均达到其梁弯曲能力,随后梁端角焊缝断裂,以及节理区内缩减钢截面断裂。三个II型接头的柱子和梁截面尺寸与I型试样相同。主要试验参数为梁端附加的抗弯钢筋和轴向荷载比。所有II型试件均达到其梁弯曲能力,随后梁端的热影响区断裂。所有试件均具有延展性,具有良好的滞后性能,并符合验收标准。根据测试和分析结果提出设计考虑因素。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号