首页> 外文期刊>Analytical methods >Preparation of matrix-matched standards for the analysis of teeth via laser ablation-inductively coupled plasma-mass spectrometry
【24h】

Preparation of matrix-matched standards for the analysis of teeth via laser ablation-inductively coupled plasma-mass spectrometry

机译:Preparation of matrix-matched standards for the analysis of teeth via laser ablation-inductively coupled plasma-mass spectrometry

获取原文
获取原文并翻译 | 示例
           

摘要

Mineralised tissue such as teeth can serve as a retrospective, chronological bioindicator of past exposure to toxic metals. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) can be used to determine the presence and spatial distribution of toxic metals in teeth, giving a record of when an exposure occurred. Concentrations of these metals are often determined by a one-point calibration against NIST glass using an equation that requires an internal standard factor that accounts for differences in ablation behaviour between the glass and the tooth. However, an ideal external calibration would contain multiple matrix-matched standards to obtain a calibration curve. Here, we investigated optimal procedures for preparing synthetic hydroxyapatite (HA) doped with elements of interest as a calibration material. The materials were examined for homogeneity of metal incorporation, matrix-matched ablation characteristics, linearity, and limits of detection. A homogenised and pelleted HA was the most suitable material, providing improved ablation characteristics over previous HA materials and NIST glass for the analysis of teeth. An ablation yield of 1.1 showed its suitability to analyse teeth, the metals were homogeneously incorporated, and it produced excellent linearity with limits of detection ranging from 0.1-2 mg kg~(-1) for magnesium, aluminium, nickel, copper, zinc, cadmium, barium and lead. A juvenile incisor from a remote indigenous community in Australia and an adult molar from Sri Lanka were assessed for toxic metal exposure. The molar showed evidence of exposure to cadmium and lead. The synthetic HA material was straightforward to prepare, and will improve confidence in the analysis of teeth and other biomineralised material when assessing toxic metal exposure.

著录项

  • 来源
    《Analytical methods》 |2023年第6期|797-806|共10页
  • 作者单位

    Hyphenated Mass Spectrometry Laboratory (HyMaS), School of Mathematical and Physical Sciences, Faculty of Science, University of Technology Sydney, P. O. Box 123, Broadway, NSW 2007, Australia.;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 英语
  • 中图分类 分析化学;
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号