首页> 外文期刊>Journal of interventional cardiac electrophysiology: an international journal of arrhythmias and pacing >Early recurrence of atrial fibrillation after pulmonary vein isolation: a comparative analysis between cryogenic and contact force radiofrequency ablation
【24h】

Early recurrence of atrial fibrillation after pulmonary vein isolation: a comparative analysis between cryogenic and contact force radiofrequency ablation

机译:Early recurrence of atrial fibrillation after pulmonary vein isolation: a comparative analysis between cryogenic and contact force radiofrequency ablation

获取原文
获取原文并翻译 | 示例
           

摘要

Background Early recurrence (ER) of atrial fibrillation (AF) within 90 days post-ablation is observed in up to 50% of patients and has been attributed to transient inflammation. The importance of ER in current era of pulmonary vein isolation (PVI) with cryoballoon ablation (CBA) and contact-force catheter radiofrequency ablation (cfRFA) has not been clearly reported. In addition, it is not known whether there are differences between types of ablation energy used during PVI. Methods Study population was drawn from a prospective multicenter database of AF ablation. Consecutive patients undergoing first-time ablation with PVI alone, using either second-generation CBA or cfRFA catheters were included. Patients were followed at 0.5, 3, 6, and 12 months to assess recurrence. Predictors of late recurrence (LR), defined as recurrence outside the blanking period, were assessed by Cox proportional hazards regression models. Freedom from LR was calculated and compared between two groups using the Kaplan-Meier method and log-rank test. Results Study cohort included 300 patients (1:1 CBA:RFA, age 63.6 +/- 10.3 years, 67% male). There were no baseline characteristic differences between the CBA and cfRFA groups. ER occurred in 23.3% and 16.7% of patients in the CBA and cfRFA groups, respectively (p = 0.149). One-year freedom from LR was similar for both groups (72.7% CBA vs. 78% cfRFA, p = 0.287). Fifty-two patients (25 CBA and 27 cfRFA) underwent repeat ablation and no difference in durability of PVI was found. ER was the only common independent predictor of LR for either group and for the entire cohort (HR 2.3). Conclusions In our series of AF ablation using second-generation cryoballoon and contact-force RFA catheters, recurrence in the "blanking period" is seen in 20% and remains predictive of late recurrence irrespective of the energy used.
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号