BACKGROUND: The initial electronic apex locator (EAL) length measurement is generally established with a small-sized file. It is not known whether file size would be interfering with the reading accuracy of the EAL. This study aimed to evaluate the effect of file size on the accuracy of Root ZX apex locator using an agar model when sodium hypochlorite solution or blood was present during electronic measurements in enlarged root canals. METHODS: A total of 36 extracted lower premolars were used. In stage 1, the canals were instrumented using size 10-40 K-files with a size 40 K-file as the master apical file (MAF). The teeth were then divided randomly into two groups of 18 teeth each. In group A, the teeth were mounted in one per cent agar and irrigated with six per cent sodium hypochlorite solution (NaOCl), while in group B the teeth were mounted in agar and irrigated with human blood. In stage 2, the canals were enlarged using a size 60 K-file as the MAF. In stages 1 and 2, the apical portions of the canals were instrumented using the step-back sequence (up to a size 80 K-file). In stage 3, the canals were enlarged using a size 80 K-file as the MAF. In each stage, the length was measured with a Root ZX until the meter value reached 'APEX' using small and large size files. RESULTS: Three-way ANOVA and Bonferroni test showed that file size, stage of preparation and type of irrigant all had a significant influence on the measurement error (P < 0.0001), with all the interactions between these three factors being significant (P < 0.0001). CONCLUSIONS: As the diameter of the root canal increased, the measured length with the smaller size files became shorter. A file of a size close to the prepared canal diameter should be used for root length measurement in the presence of blood. In the presence of NaOCl, the Root ZX was highly accurate even when the file was much smaller than the diameter of the canal. The agar model was effective and suitable for testing EALs in vitro.
机译:背景:最初的电子顶点定位器(EAL)长度测量通常使用小文件来建立。尚不知道文件大小是否会影响EAL的读取精度。这项研究旨在使用琼脂模型评估在扩大的根管中进行电子测量时存在次氯酸钠溶液或血液时文件大小对Root ZX根尖定位器准确性的影响。方法:共提取了36个下颌前磨牙。在第1阶段中,使用10-40 K尺寸锉刀和40 K尺寸锉刀作为根尖锉(MAF)来测量运河。然后将牙齿随机分为两组,每组18个牙齿。在A组中,将牙齿安装在1%的琼脂中,并用6%的次氯酸钠溶液(NaOCl)冲洗;而在B组中,将牙齿安装在琼脂中,并用人血冲洗。在第2阶段,使用大小为60 K的锉刀作为MAF扩大运河。在第1和第2阶段中,使用后退顺序(最大80 K锉)对根管部分进行器械检查。在第3阶段,使用大小为80 K的锉刀作为MAF扩大运河。在每个阶段,使用Root ZX测量长度,直到使用小尺寸和大尺寸文件测量仪的值达到“ APEX”为止。结果:三因素方差分析和Bonferroni测试表明,文件大小,制备阶段和冲洗剂类型均对测量误差有显着影响(P <0.0001),这三个因素之间的所有相互作用均显着(P <0.0001) )。结论:随着根管直径的增加,使用较小尺寸锉的测量长度变短。在有血的情况下,应使用尺寸接近准备好的根管直径的锉刀进行牙根长度测量。在存在NaOCl的情况下,即使锉刀的直径远小于根管的直径,Root ZX也非常准确。琼脂模型是有效的,适合于体外测试EAL。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号