首页> 外文期刊>Archives of orthopaedic and trauma surgery. >A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis
【24h】

A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis

机译:A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Introduction It is clinically important to analyze the initial contact state between an implant and femoral cortical bone as it affects clinical outcomes, such as stress shielding, stem subsidence, thigh pain, and patient-reported outcomes after total hip arthroplasty. Whether the initial contact state of a double-tapered fully hydroxyapatite (HA)-coated stem is achieved with the preserved cancellous or cortical bone remains to be established. This study aimed to compare the contact area with the femoral cortical bone between a double-tapered fully HA-coated stem (HA group) and a tapered wedge cementless stem (TW group) using three-dimensional computed tomography (3DCT)-based templating software. Materials and methods Forty-seven total hip arthroplasties in the HA and TW groups each were retrospectively analyzed. The contact area between the implant and femoral cortical bone in the whole stem and at each Gruen zone was measured using density mapping with 3DCT-based templating software. Results The demographic data were not significantly different between the two groups. The contact area in the whole stem area was lower in the HA group (HA 5.4 +/- 1.8% vs. TW 9.0 +/- 4.8%, p < 0.01). The HA group had a lower contact area in zone 2 (HA 6.7 +/- 6.5% vs. TW 15.6 +/- 10.8%, p < 0.01) and zone 6 (HA 1.8 +/- 3.5% vs. TW 6.3 +/- 3.6%, p < 0.01) than the TW group. The implant type (beta = 0.41, p < 0.01) and stem coronal alignment (beta = - 0.29, p < 0.01) were significant predictors of the contact area in the whole stem area in a multiple regression analysis (adjusted R-2 = 0.27, p < 0.01). Conclusion The contact area of the double-tapered fully HA-coated stem was significantly lower than that of the tapered wedge cementless stem.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号