Ultrasound-assisted dispersive liquid-liquid microextraction coupled with field-amplified capillary electrophoresis for sensitive and quantitative determination of fluoxetine and norfluoxetine enantiomers in biological fluids

机译:Ultrasound-assisted dispersive liquid-liquid microextraction coupled with field-amplified capillary electrophoresis for sensitive and quantitative determination of fluoxetine and norfluoxetine enantiomers in biological fluids

获取原文
获取原文并翻译 | 示例
           

摘要

A rapid, simple, and sensitive technique for the quantitative detection of fluoxetine and norfluoxetine enantiomers in biological fluids was developed based on the combination of field-amplified sample stacking (FASS)-related capillary electrophoresis (CE) with ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME). The extraction efficiency of UA-DLLME was strongly related to extraction time, salt concentration, type of extraction and dispersion solvents, and volume of extraction and dispersion solvents. The extracted fluoxetine and norfluoxetine enantiomers in a mixture of 50% methanol and 50% deionized water were efficiently stacked using FASS and then separated using cyclodextrin-modified CE. Under optimal conditions of FASS (chiral selector, 3 mM trimethyl-beta-cyclodextrin; and background electrolyte, 100 mM phosphate buffer) and UA-DLLME (extraction solvent, 200 mu L of acetone; and dispersed solvent, 50 mu L of C2H2Cl4 in 1 mL of the sample solution), the obtained enrichment factors of fluoxetine and norfluoxetine enantiomers reached approximately 2000. The linear ranges for the quantification of fluoxetine and norfluoxetine enantiomers were 0.3-150 and 0.6-150 nM, respectively. The relative standard deviations in peak areas and migration time for four analytes were less than 3.3% and 6.3%, respectively. The proposed system provided limits of detection (signal-to-noise ratio of 3) for four analytes corresponding to 0.1 nM. The precision and accuracy for urine and serum samples were less than 6.8 and 8.3%, respectively. These findings suggested that the proposed system exhibited a high potential for the reliable determination of fluoxetine and norfluoxetine enantiomers in clinical samples.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号