首页> 外文期刊>Muscle and Nerve >A novel diagnostic method for myasthenia gravis
【24h】

A novel diagnostic method for myasthenia gravis

机译:一种新型重症肌无力的诊断方法

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Introduction/Aims Videonystagmography (VNG) which directly records eye movements using infrared video goggles with mini-cameras, is used to measure nystagmus. Our aim is to explore whether VNG can be used to detect a decrement in the extraocular muscle (EOM) activity of patients with myasthenia gravis (MG). Methods Thirty-four patients with MG, including 13 with ocular-predominant and 21 with generalized MG, and 23 healthy controls participated. Using VNG we recorded the velocity of the eye movements of the patients as they followed a moving target. We then calculated the gain by dividing the eye movement velocity (degrees/second) by the target velocity (degrees/second). Results In MG subjects, the mean initial gain (maximum gain) was 1.23 +/- 0.31 (range: 0.63-2.15) for the right eye and 1.22 +/- 0.37 (range; 0.60-2.28) for the left eye. The mean minimum gain was 0.11 +/- 0.12 (0.01-0.58) for the right and 0.14 +/- 0.5 (0.02-0.55) for the left. Due to fatigue, the movement gain was reduced by 91.7 in the right eye and 88.2 in the left eye. After reaching minimum velocity, gain remained at a minimum for a mean of 1.08 +/- 0.52 (0.3-2.4) s for the right and 1.49 +/- 0.85 (0.4-3.6) s for the left, before the velocity increased again. There was no fatigue-induced decrement in healthy subjects. Discussion Our study documents a decrement in EOM activity recorded by VNG in patients with MG which begins to improve within 1-2 s after reaching minimum velocity, analogous to traditional low-frequency repetitive nerve stimulation testing and its U-shaped pattern. Thus, VNG may be a promising diagnostic test for MG.
机译:简介/目的 视频眼震造图(VNG)使用带有微型摄像头的红外视频护目镜直接记录眼球运动,用于测量眼球震颤。我们的目的是探索 VNG 是否可用于检测重症肌无力 (MG) 患者眼外肌 (EOM) 活动的下降。方法 选取34例MG患者,其中以眼为主,全身MG为21,健康对照者23例。使用VNG,我们记录了患者在跟随移动目标时眼球运动的速度。然后,我们通过将眼球运动速度(度/秒)除以目标速度(度/秒)来计算增益。结果 在MG受试者中,右眼的平均初始增益(最大增益)为1.23 +/- 0.31(范围:0.63-2.15),左眼为1.22 +/- 0.37(范围:0.60-2.28)。右侧的平均最小增益为 0.11 +/- 0.12 (0.01-0.58),左侧为 0.14 +/- 0.5 (0.02-0.55)。由于疲劳,右眼的运动增益减少了91.7%,左眼的运动增益减少了88.2%。达到最小速度后,增益保持在最小值,右侧平均为 1.08 +/- 0.52 (0.3-2.4) s,左侧平均为 1.49 +/- 0.85 (0.4-3.6) s,然后速度再次增加。在健康受试者中没有疲劳诱导的下降。讨论 我们的研究记录了 VNG 记录的 MG 患者 EOM 活性的下降,在达到最小速度后 1-2 秒内开始改善,类似于传统的低频重复神经刺激测试及其 U 形模式。因此,VNG 可能是一种很有前途的 MG 诊断测试。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号