首页> 外文期刊>Innovative Infrastructure Solutions >Shear connector systems for composite beam with cold?formed steel of lipped C?channel section
【24h】

Shear connector systems for composite beam with cold?formed steel of lipped C?channel section

机译:Shear connector systems for composite beam with cold?formed steel of lipped C?channel section

获取原文
获取原文并翻译 | 示例
           

摘要

Headed stud is well-known shear connector, which is usually welded to the steel beam of the composite beams to connect thesteel beam to the concrete slab to achieve the required composite action and limits the interface slip. Despite the efficiency ofusing the headed studs for Hot-Rolled Steel beams and steel plate girders, the application of headed studs may not be practicalfor very thin beam section such as cold-formed steel (CFS) sections due to the limitation of welding of the thin-walled steelsections. Thus, this study proposes innovative shear connector systems for composite cold-formed steel–concrete beams. Thebehaviour of the shear connector systems, including embedded CFS beam with/without holes, U-shaped steel bar embeddedfrom top, embedded CFS beam and steel bar at the sides, embedded CFS beam with Bent-up tabs, and brackets at the topand bottom, were experimentally investigated through push-out tests in accordance with Eurocode 4 using 8 specimens ofcomposite beam using different orientation. Experimental tests were aimed to determining the maximum resistance of theproposed shear connectors. The results indicated that the strength of a shear connector was very reliant on its deformationand the crushing of concrete. The ductile behaviour of most of the tested shear connectors satisfied the ductility requirementsof Eurocode 4. In this study, it was concluded that the proposed shear connectors are suitable for the construction ofcomposite beams with CFS.

著录项

  • 来源
    《Innovative Infrastructure Solutions》 |2023年第3期|91.1-91.22|共22页
  • 作者单位

    School of Civil Engineering, Faculty of Engineering,Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor,Malaysia;

    Institute of Smart Infrastructure and Innovative Construction,Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor,Malaysia,School of Civil Engineering, Universiti Teknologi Malaysia,Johor Bahru, 81310 Johor, Malaysia;

    Civil Engineering Department, Faculty of Engineering,Sriwijaya University, Jalan Srijaya Negara, Bukit Besar,Palembang 30139, IndonesiaSchool of Civil Engineering, Universiti Teknologi Malaysia,Johor Bahru, 81310 Johor, MalaysiaInstitute of Smart Infrastructure and Innovative Construction,Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor,Malaysia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 英语
  • 中图分类
  • 关键词

    Shear connector; Push-out test; Cold-formed steel; Composite beam;

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号