首页> 外文期刊>European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society >Comparison of radiation exposure and surgery time between an intraoperative CT with automatic surface registration and a preoperative CT with manual surface registration in navigated spinal surgeries
【24h】

Comparison of radiation exposure and surgery time between an intraoperative CT with automatic surface registration and a preoperative CT with manual surface registration in navigated spinal surgeries

机译:Comparison of radiation exposure and surgery time between an intraoperative CT with automatic surface registration and a preoperative CT with manual surface registration in navigated spinal surgeries

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose This retrospective matched case-control study was conducted to compare two CT based surgery techniques for navigated screw placement in spinal surgery, whether a reduction of radiation exposure and surgery time could be achieved. Methods We matched cases treated with an intraoperative CT (iCT), regarding the type and number of implants, with cases treated with a preoperative CT (pCT) of one main surgeon. Outcome measures were radiation exposure due to intraoperative control x-rays, radiation exposure due to CT images, and the duration of surgery. Results The required radiation exposure could be significantly reduced in the iCT group. For the intraoperative control X-rays by 69% (median (MED) 88.50/standard deviation (SD) 107.84 and MED 286.00/SD 485.04 for iCT and pCT respectively-in Gycm(2); p < 0.001) and for the CT examinations by 25% (MED 317.00/SD 158.62 and MED 424.50/SD 225.04 for iCT and pCT respectively-in mGycm; p < 0.001) with no significant change in surgery time. The correlation between the number of segments fused and the necessary surgery time decreased significantly for the iCT group (Pearson product-moment-correlation: r = 0.569 and r = 0.804 for iCT and pCT respectively; p < 0.05). Conclusion The results show that spinal navigation using an intraoperative CT with automatic registration compared to a preoperative CT and intraoperative manual surface registration, allows a significant reduction of radiation exposure, without prolonged surgery time. A significant benefit regarding cut-to-suture-time can be gained with surgeries of a larger scale.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号