首页> 外文期刊>Biocybernetics and biomedical engineering >The effect of type of filters and collimators on the SPEGT axis of rotation error
【24h】

The effect of type of filters and collimators on the SPEGT axis of rotation error

机译:滤光片和准直器的类型对SPEGT旋转轴误差的影响

获取原文
获取原文并翻译 | 示例

摘要

High resolution and artifact free SPEGT reconstruction of the distribution of radioactive sources over the entire imaging field requires exact alignment between the electronic and the mechanical axis of rotations. In this paper, the effect of misalignment between the electronic and the mechanical axis of rotations of SPECT system equipped with low-energy high-resolution and low-energy general-purpose collimators through the field of view has been studied. In addition, the useful dimensions of the SPECT field of view without artifact due to axis of rotation error have been calculated. Furthermore, the roles of digital filters in reducing this effect have been studied.
机译:高分辨率和无伪像的SPEGT重建整个成像场中放射源的分布要求在旋转的电子轴和机械轴之间进行精确对准。在本文中,通过视场研究了配备有低能耗高分辨率和低能耗通用准直仪的SPECT系统的电子旋转轴与机械旋转轴之间的未对准效应。另外,已经计算了没有旋转误差导致的伪影的SPECT视场的有用尺寸。此外,已经研究了数字滤波器在减小这种影响中的作用。