...
首页> 外文期刊>Pesticide science >Measured and computed concentrations of 1,3‐dichloropropene in the air around fumigated fields
【24h】

Measured and computed concentrations of 1,3‐dichloropropene in the air around fumigated fields

机译:测量和计算熏蒸场周围空气中 1,3-二氯丙烯的浓度

获取原文

摘要

AbstractConcentration patterns of both isomers of 1,3‐dichloropropene in air around two fields were computed with a gaussian plume model for six time intervals after injection of the fumigant into the soil and compared with concentrations measured in the air. During the first three days after the injection of 1,3‐dichloropropene into the soil of one field, the downwind concentrations of 1,3‐dichloropropene in air computed for a height of 1.5 m above the ground ranged up to 19 μg m−3, whereas the downwind concentrations measured ranged up to 29 μg m−3. For the period from five to ten days after injection, the concentrations computed and those measured ranged up to 36 μg m−3and 16 μg m−3, respectively. For the other field, the computed downwind concentrations in air ranged up to 0.6 μg m−3during the first three days after injection, whereas those measured ranged up to 23 μg m−3. For the period from four to nine days after injection, the concentrations computed and those measured ranged up to 2.3 and 1.3 μg m−3, respectively. The computations under‐estimated the concentrations in air during the first three days following application, but on later days the computed and measured concentrations w
机译:摘要采用高斯羽流模型计算了1,3-二氯丙烯在土壤中注入土壤后6个时间间隔内的两种异构体在2个田体周围空气中的浓度模式,并与空气中测得的浓度进行了比较。在将1,3-二氯丙烯注入一块田地土壤后的前三天,在离地面1.5 m的高度计算的空气中1,3-二氯丙烯的下风浓度范围为19 μg m-3,而下风向测得的浓度范围为29 μg m-3。在注射后5至10天期间,计算的浓度和测量的浓度分别高达36μgm-3和16μgm-3。对于另一个领域,在注入后的前三天,计算出的空气中顺风浓度范围高达0.6 μg m−3,而测量的浓度范围高达23 μg m−3。在注射后4至9天期间,计算的浓度和测量的浓度分别高达2.3和1.3μgm−3。计算低估了施用后前三天空气中的浓度,但在后来的日子里,计算和测量的浓度 w

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号