首页> 外文期刊>Atomic Spectroscopy >On-line Solid Phase Extraction of Nickel, Copper, and Cadmium Using a Newly Synthesized Polyamine Silica Gel-loaded Mini-column for Flame Atomic Absorption Spectrometric Determination
【24h】

On-line Solid Phase Extraction of Nickel, Copper, and Cadmium Using a Newly Synthesized Polyamine Silica Gel-loaded Mini-column for Flame Atomic Absorption Spectrometric Determination

机译:新型负载聚胺硅胶的微型柱在线固相萃取镍,铜和镉,用于火焰原子吸收光谱法测定

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this study, polyamine (pentaethylene hexamine) functionalized silica gel (PA-SG) was prepared as a novel sorbent material for on-line preconcentration of Cd(II), Cu(II), and Ni(II) from complex matrices. The PA-SG was characterized by means of elemental analysis and FT-IR spectroscopic techniques. The effective parameters for on-line preconcentration and separation of Cd(II), Cu(II), Ni(II), and FAAS detection were optimized by investigating the effects of sample pH, type, and concentration of eluent, flow rate of sample and eluent, loop volume, and matrix ions. The linear range of the proposed method was betweenl0-200 μg L~(-1) for each element, with enrichment factors of 39.9, 30.4, and 43.6 and detection limits of 0.19, 0.73, and 0.91 μg L~(-1) for Cd(II), Cu(II), and Ni(II), respectively, by loading 5.0 mL of sample solution. The precision of the method (evaluated as the relative standard deviation obtained after analyzing 11 samples with three replicates each) was determined as 3.2, 2.4, and 4.0% for 20 μg L~(-1) of Cd(II), 0.1 mg L~(-1) of Cu(II) and Ni(II), respectively, by loading 5.0 mL of sample solution. The sorption capacities of PA-SG were 41.4, 33.1, and 23.7 mg for Cd(II), Cu(II), and Ni(II) per gram of resin, respectively. The accuracy of the proposed on-line preconcentration procedure was evaluated by analyzing reference materials CTA-VTL-2 Virginia Tobacco Leaves and NWTM-15.2 Water - Trace Elements. Application of the proposed procedure was successfully accomplished for the analysis of natural water and food samples.
机译:在这项研究中,聚胺(五亚乙基六胺)功能化硅胶(PA-SG)被制备为一种新型吸附剂材料,用于从复杂基质中在线富集Cd(II),Cu(II)和Ni(II)。通过元素分析和FT-IR光谱技术对PA-SG进行了表征。通过研究样品pH,类型,洗脱液浓度,样品流速的影响,优化了Cd(II),Cu(II),Ni(II)和FAAS在线在线富集和分离的有效参数。所提方法的线性范围为每个元素10-200μgL〜(-1),富集系数分别为39.9、30.4和43.6,检出限为0.19、0.73,负载5.0 mL样品溶液分别测定Cd(II),Cu(II)和Ni(II)的L〜(-1)和0.91μgL〜(-1)。分别分析了11个样品,每个样品有3个重复样品)对于20μgL〜(-1)的Cd(II),0.1 mg L〜(-1)的Cu(II)和Ni(II)分别为3.2%,2.4%和4.0% ),分别加入5.0 mL样品溶液,每克树脂对Cd(II),Cu(II)和Ni(II)的吸附容量分别为41.4、33.1和23.7 mg。建议的在线预检的准确性通过分析参考材料CTA-VTL-2弗吉尼亚烟叶和NWTM-15.2水-痕量元素来评估浓缩过程。所提出程序的应用已成功完成,用于分析天然水和食物样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号