首页> 外文期刊>Journal of clinical laser medicine and surgery >Laser and Curing Light Inducedin VitroPulpal Temperature Changes
【24h】

Laser and Curing Light Inducedin VitroPulpal Temperature Changes

机译:Laser and Curing Light Inducedin VitroPulpal Temperature Changes

获取原文
       

摘要

ABSTRACTObjective:This study was conducted to comparein vitropulp chamber temperature changes induced by conventional curing light and argon laser under common conditions.Summary Background Data:Previousin vitrostudies have shown that impacting the surface of teeth with either an argon laser or conventional curing light causes pulp temperature increases of various degrees.Methods:The sample tooth had a class V composite restoration placed with 2.48-mm distance from the surface of the composite to a Thermister Thermometer. The thermometer was inserted into the cutaway pulp chamber to measure the temperature increase from stabilized room temperature, which was caused by exposure to argon laser or conventional curing light.Results:Temperature increases for the argon laser for the recommended curing time were 3°F or less. The longer the exposure times for either method of curing, the higher the temperature increased.Conclusion:At recommended curing times,in vitropulp chamber temperature increases from laser units were significantly lower than those of the conventional curing lights