...
首页> 外文期刊>The Journal of Hand Surgery Asian-Pacific Volume >A Novel Technique for Dynamic External Fixation of Proximal Interphalangeal Joint Fracture-Dislocations
【24h】

A Novel Technique for Dynamic External Fixation of Proximal Interphalangeal Joint Fracture-Dislocations

机译:一种近端指间关节骨折脱位动态外固定的新技术

获取原文
获取原文并翻译 | 示例

摘要

Background: The pins and rubbers traction system is widely used to treat unstable proximal interphalangeal (PIP) joint fracture-dislocations. However, dealing with rubber bands can be difficult due to its elasticity and weakness. The purpose of this study was to report the results of an alternative dynamic external fixator technique for unstable PIP joint injuries. Methods: Thirteen patients with acute unstable PIP joint fracture-dislocation (n = 8), pilon fracture (n = 2), or comminuted shaft fractures of a middle phalanx with or without PIP joint extension (n = 3) were enrolled. The alternative fixator used a plastic syringe to maintain distraction force instead of the commonly used rubber bands. Four patients underwent combined open reduction due to unsatisfactory reduction by closed mean. The fixator was removed when there was radiographic evidence of healing. Results: At 6 months after the operation, the mean active ROM of the injured PIP joint was 89 degrees (range, 70-104 degrees), and the mean Quick-DASH score was 9.78 (range, 0-40.9). The mean NRS of pain before fixator removal was 1 (range, 0-4). One patient had a pin tract infection and underwent debridement and fixator removal at 33 days postoperatively. There was no loss of reduction or implant failure in the study. Conclusions: The results were comparable to other dynamic external fixation techniques used for unstable PIP joint fracture-dislocations. The main advantages of this technique were strength of the system, procedure simplicity, the compact design, and relatively low cost. In addition, this technique can also be used in pilon fractures and comminuted shaft fractures of a middle phalanx with or without PIP joint extension.
机译:背景:销钉和橡胶牵引系统广泛用于治疗不稳定的近端指间 (PIP) 关节骨折脱位。然而,由于橡皮筋的弹性和弱点,处理橡皮筋可能很困难。本研究的目的是报告替代动态外固定器技术治疗不稳定 PIP 关节损伤的结果。方法:选取13例急性不稳定PIP关节骨折脱位(n=8)、桩状骨折(n=2)或中指骨粉碎性干骨折伴或不伴PIP关节伸展(n=3)的患者。替代固定器使用塑料注射器来保持牵引力,而不是常用的橡皮筋。4 例患者因闭合均值复位不满意而接受联合切开复位。当有愈合的放射学证据时,固定器被移除。结果:术后6个月,受伤PIP关节平均活动ROM为89度(范围,70-104度),平均Quick-DASH评分为9.78(范围,0-40.9)。移除固定器前疼痛的平均 NRS 为 1(范围,0-4)。1例患者出现针道感染,术后33天行清创术和固定器拔除术。该研究中没有复位损失或植入失败。结论:该结果与其他用于不稳定PIP关节骨折脱位的动态外固定技术相当。该技术的主要优点是系统强度大、程序简单、设计紧凑、成本相对较低。此外,该技术还可用于中指骨的桩状骨折和粉碎性轴骨折,伴或不伴 PIP 关节伸展。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号