首页> 外文期刊>Artificial Organs >The Relationship Between R-Wave Magnitude and Ventricular Volume During Continuous Left Ventricular Assist Device Assistance: Experimental Study
【24h】

The Relationship Between R-Wave Magnitude and Ventricular Volume During Continuous Left Ventricular Assist Device Assistance: Experimental Study

机译:连续左心室辅助装置辅助期间R波幅度与心室容积的关系:实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

The current use of left ventricular assist devices (LVADs) as destination therapy is associated with the clinical need of monitoring patient-pump interaction. To this aim, the present work investigated the possibility of getting useful information about the status of the assisted left ventricle using electrocardiographic (ECG) data. A total of six animals, undergoing Gyro Centrifugal Pump 2 implantation (a new version of Gyro Centrifugal Pump C1E3 [Kyocera Corporation, Kyoto, Japan]) and CircuLite Synergy Micropump (CircuLite, Inc., Saddlebrooke, NJ, USA) in atrio-aortic connection, were analyzed. Data refer to different LVAD speeds with consequently different levels of ventricular unloading. From ECG signal, the R wave peak was individuated together with the corresponding left ventricular volume. Then on both signals, a moving average analysis was performed to reduce the effect of the ventilation. A regression and correlation analysis performed on the two resulting signals evidenced that the R wave peak and the ventricular volume are strictly related. Specifically, any change of LVAD speed, inducing a change in ventricular volume, is associated with a change in R wave peak value. The present work is a first step in investigating the usefulness of the ECG signal during LVAD therapy, for the monitoring of mechanical parameters of the heart such as the ventricular volumes. The correlation found between the ECG and the ventricular volume can be a promising starting point for possible future noninvasive LVAD patient monitoring.
机译:当前使用左心室辅助设备(LVAD)作为目的地疗法与监测患者-泵相互作用的临床需求有关。为此,本研究调查了使用心电图(ECG)数据获得有关辅助左心室状态的有用信息的可能性。总共六只动物在房主动脉中进行了Gyro离心泵2植入(Gyro离心泵C1E3的新版本[Kyocera Corporation,日本京都])和CircuLite Synergy微型泵(CircuLite,Inc.,美国新泽西州萨德尔布鲁克)。连接,进行了分析。数据涉及不同的LVAD速度,因此心室卸载水平也不同。从ECG信号中,可以将R波峰与相应的左心室容积分开。然后对这两个信号进行移动平均分析以减少通风的影响。对两个结果信号进行的回归和相关分析表明,R波峰和心室容积是严格相关的。具体地,引起心室容积变化的LVAD速度的任何变化都与R波峰值的变化相关。本工作是调查LVAD治疗期间ECG信号用于监测心脏机械参数(例如心室容积)的有用性的第一步。心电图和心室容积之间的相关性可能是未来可能的无创LVAD患者监测的有希望的起点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号