首页> 外文期刊>Artificial Organs >Clinical results and pump analysis of the gyro pump for long-term extracorporeal life support.
【24h】

Clinical results and pump analysis of the gyro pump for long-term extracorporeal life support.

机译:陀螺泵的临床结果和泵分析可为体外长期生命提供支持。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Rescuing patients in severe cardiac failure with extracorporeal support remains challenging. The Gyro pump is a centrifugal blood pump and was now used for cardiopulmonary bypass, although it was originally developed for long-term cardiac assist. Little is known about clinical experiences using this pump. Here, we report on the clinical results of long-term extracorporeal life support for over 4 days using the Gyro pump with Excelung, a hollow fiber oxygenator coated with silicone and heparin. Seven patients underwent extracorporeal life support with 15 pump and oxygenator combinations. Gyro and Excelung were used for venoarterial extracorporeal support in six patients and for right ventricular support in one patient. Patient characteristics, pump driving conditions, and blood chemistry were obtained retrospectively. All pumps were subsequently disassembled and examined macroscopically, with 6 of 15 pumps also examined by scanning electron microscopy (SEM). The patient mortality rate was 57.1%. Mean duration of support was 10.5?±?7.2 days per pump and oxygenator combination. Lactate dehydrogenase and aspartate aminotransferase were generally maintained below 1000 and 100?IU/L, respectively, after the first 4 days of pump driving. Thrombi were found in two pumps, one used without anticoagulation and the other driven at a very slow rotational speed. SEM revealed no wear in the male bearings and very low wear and deformation (0.02?±?0.03?mm) in the female bearings. The combination of Gyro and Excelung may be applicable for long-term biventricular and right ventricular support, although proper anticoagulation should be administrated to avoid thrombus formation inside the pump.
机译:在体外支持下挽救严重心力衰竭的患者仍然具有挑战性。陀螺泵是一种离心式血泵,尽管最初是为长期心脏辅助而开发的,但现在已用于体外循环。关于使用该泵的临床经验知之甚少。在这里,我们报告了使用带有Excelung的Gyro泵进行4天以上长期体外生命支持的临床结果,Excelung是一种涂有硅酮和肝素的中空纤维充氧器。 7名患者接受了15种泵和氧合器的体外生命支持。陀螺仪和Excelung用于6例患者的静脉动脉体外支持和1例患者的右心室支持。回顾性地获得患者特征,泵驱动状况和血液化学。随后将所有泵拆开并进行宏观检查,其中15台泵中有6台也通过扫描电子显微镜(SEM)进行了检查。患者死亡率为57.1%。每个泵和充氧器的平均支持时间为10.5±±7.2天。泵驱动头4天后,乳酸脱氢酶和天冬氨酸转氨酶通常分别维持在1000和100?IU / L以下。在两台泵中发现了血栓,其中一台未使用抗凝剂,另一台以非常低的转速驱动。 SEM显示,外螺纹轴承无磨损,而内螺纹轴承的磨损和变形极低(0.02±±0.03mm)。陀螺仪和Excelung的组合可能适用于长期的双心室和右心室支持,尽管应进行适当的抗凝治疗,以避免泵内形成血栓。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号