The Aachen MiniHLM--a miniaturized heart-lung machine for neonates with an integrated rotary blood pump.

机译:亚琛(Aachen)MiniHLM-微型新生儿肺心机,带有集成式旋转血泵。

获取原文
获取原文并翻译 | 示例
           

摘要

The operation of congenital heart defects in neonates often requires the use of heart-lung machines (HLMs) to provide perfusion and oxygenation. This is prevalently followed by serious complications inter alia caused by hemodilution and extrinsic blood contact surfaces. Thus, one goal of developing a HLM for neonates is the reduction of priming volume and contact surface. The currently available systems offer reasonable priming volumes for oxygenators, reservoirs, etc. However, the necessary tubing system contains the highest volumes within the whole system. This is due to the use of roller pumps; hence, the resulting placement of the complete HLM is between 1 and 2 m away from the operating table due to connective tubing between the components. Therefore, we pursued a novel approach for a miniaturized HLM (MiniHLM) by integrating all major system components in one single device. In particular, the MiniHLM is a HLM with the rotary blood pump centrically integrated into the oxygenator and a heat exchanger integrated into the cardiotomy reservoir which is directly connected to the pump inlet. Thus, tubing is only necessary between the patient and MiniHLM. A total priming volume of 102 mL (including arterial filter and a/v line) could be achieved. To validate the overall concept and the specific design we conducted several in vitro and in vivo test series. All tests confirm the novel concept of the MiniHLM. Its low priming volume and blood contact surface may significantly reduce known complications related to cardiopulmonary bypass in neonates (e.g., inflammatory reaction and capillary leak syndrome).
机译:新生儿中的先天性心脏缺陷手术通常需要使用心肺机(HLM)进行灌注和充氧。这通常主要是由于血液稀释和外在血液接触表面引起的严重并发症。因此,开发用于新生儿的HLM的一个目标是减少启动体积和接触表面。当前可用的系统为充氧器,储气罐等提供了合理的灌注体积。但是,必要的管路系统包含整个系统中最大的体积。这是由于使用了滚子泵。因此,由于部件之间的连接管,整个HLM的最终放置位置距离手术台1-2 m。因此,我们通过将所有主要系统组件集成到一个设备中,为微型HLM(MiniHLM)寻求了一种新颖的方法。尤其是,MiniHLM是一种HLM,其旋转式血泵在中心处集成到充氧器中,而热交换器则集成在直接连接到泵入口的心脏切开术储液器中。因此,仅在患者和MiniHLM之间需要管道。可以达到102毫升的总灌注体积(包括动脉过滤器和a / v管路)。为了验证总体概念和具体设计,我们进行了几个体外和体内测试系列。所有测试都证实了MiniHLM的新颖概念。它的低启动体积和血液接触表面可显着减少与新生儿体外循环有关的已知并发症(例如,炎症反应和毛细血管渗漏综合征)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号