Characterizing left ventricular mechanical and electrical activation in patients with normal and impaired systolic function using a non-fluoroscopic cardiovascular navigation system

机译:Characterizing left ventricular mechanical and electrical activation in patients with normal and impaired systolic function using a non-fluoroscopic cardiovascular navigation system

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose Cardiac disease frequently has a degenerative effect on cardiac pump function and regional myocardial contraction. Therefore, an accurate assessment of regional wall motion is a measure of the extent and severity of the disease. We sought to further validate an intra-operative, sensor-based technology for measuring wall motion and strain by characterizing left ventricular (LV) mechanical and electrical activation patterns in patients with normal (NSF) and impaired systolic function (ISF). Methods NSF ( n ?=?10; ejection fraction?=?62.9?±?6.1%) and ISF ( n ?=?18; ejection fraction?=?35.1?±?13.6%) patients underwent simultaneous electrical and motion mapping of the LV endocardium using electroanatomical mapping and navigational systems (EnSite? NavX? and MediGuide?, Abbott). Motion trajectories, strain profiles, and activation times were calculated over the six standard LV walls. Results NSF patients had significantly greater motion and systolic strains across all LV walls than ISF patients. LV walls with low-voltage areas showed less motion and systolic strain than walls with normal voltage. LV electrical dyssynchrony was significantly smaller in NSF and ISF patients with narrow-QRS complexes than ISF patients with wide-QRS complexes, but mechanical dyssynchrony was larger in all ISF patients than NSF patients. The latest mechanical activation was most often the lateral/posterior walls in NSF and wide-QRS ISF patients but varied in narrow-QRS ISF patients. Conclusions This intra-operative technique can be used to characterize LV wall motion and strain in patients with impaired systolic function. This technique may be utilized clinically to provide individually tailored LV lead positioning at the region of latest mechanical activation for patients undergoing cardiac resynchronization therapy. Clinical trial registration URL: http://www.clinicaltrials.gov . Unique identifier: NCT01629160.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号