Golimumab trough levels, antidrug antibodies and clinical response in patients with rheumatoid arthritis treated in daily clinical practice.

机译:在日常临床实践中治疗的类风湿关节炎患者的Golimumab谷水平,抗药物抗体和临床反应。

获取原文
获取原文并翻译 | 示例
           

摘要

Osteoporosis is characterized by reduced bone strength, but no FDA-approved medical device measures bone strength. Bone strength is strongly associated with bone stiffness, but no FDA-approved medical device measures bone stiffness either. Mechanical Response Tissue Analysis (MRTA) is a non-significant risk, non-invasive, radiation-free, vibration analysis technique for making immediate, direct functional measurements of the bending stiffness of long bones in humans in vivo. MRTA has been used for research purposes for more than 20 years, but little has been published about its accuracy. To begin to investigate its accuracy, we compared MRTA measurements of bending stiffness in 39 artificial human ulna bones to measurements made by Quasistatic Mechanical Testing (QMT). In the process, we also quantified the reproducibility (i.e., precision and repeatability) of both methods. MRTA precision (1.0±1.0%) and repeatability (3.1±3.1%) were not as high as those of QMT (0.2±0.2% and 1.3+1.7%, respectively; both p<10(-4)). The relationship between MRTA and QMT measurements of ulna bending stiffness was indistinguishable from the identity line (p=0.44) and paired measurements by the two methods agreed within a 95% confidence interval of ±5%. If such accuracy can be achieved on real human ulnas in situ, and if the ulna is representative of the appendicular skeleton, MRTA may prove clinically useful.
机译:骨质疏松症的特征是骨强度降低,但是没有FDA批准的医疗器械可以测量骨强度。骨强度与骨刚度密切相关,但是没有FDA批准的医疗设备也可以测量骨刚度。机械反应组织分析(MRTA)是一项无重大风险,无创,无辐射,振动分析技术,用于对人体中长骨的弯曲刚度进行即时,直接的功能测量。 MRTA已用于研究目的已有20多年了,但是关于其准确性的报道却很少。为了开始研究其准确性,我们将MRTA在39个人造人尺骨的弯曲刚度测量结果与准静态机械测试(QMT)进行的测量结果进行了比较。在此过程中,我们还量化了这两种方法的可重复性(即精确度和可重复性)。 MRTA精度(1.0±1.0%)和可重复性(3.1±3.1%)不如QMT(分别为0.2±0.2%和1.3 + 1.7%;均p <10(-4))高。尺骨弯曲刚度的MRTA和QMT测量值之间的关系与同一性线没有区别(p = 0.44),两种方法的配对测量值在±5%的95%置信区间内一致。如果可以在真正的人类尺骨上就地获得这种准确性,并且如果尺骨代表了阑尾骨骼,那么MRTA可能被证明在临床上是有用的。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号