Shoulder arthroscopy requires on average 3.21 of pressurised irrigation fluid. Patients who are wet from leaking fluid are a common problem. We describe a draping technique to keep patients dry. The patient is placed in a lateral decubitus position. The arm is held with longitudinal skin traction. Four 60cm x 60cm fluid absorbent incontinence pads (Cover Dri, Attends Ltd, Newcastle upon Tyne, UK) are taped to the patient. Pad A is placed midway between the iliac crest and the lower margin of the rib cage and pad B along the mid-clavicular line intersecting distally with pad A. Pad C is placed lcm lateral to the lateral boarder of the scapular body intersecting with pad A, and pad P along the root of the neck intersecting with both pads B and C.
展开▼
机译:肩关节镜检查平均需要加压冲洗液3.21。漏液弄湿的患者是一个普遍的问题。我们描述了一种使患者保持干燥的悬垂技术。病人侧卧位。手臂保持纵向皮肤牵引力。将四个60cm x 60cm的液体吸收性失禁垫(英国泰恩河畔纽卡斯尔的Cover Dri,Attends Ltd)粘在病人身上。垫A沿the骨中线与pad A远端相交,放置在c顶与肋骨笼下缘和垫B之间的中间位置。垫C置于与pad A相交的肩the骨外侧边缘1cm处,然后沿着颈部的根部将P垫与B和C垫相交。
展开▼