OBJECTIVE: To investigate validity and reliability of the Functional Gait Assessment (FGA) (German version) as a measure for balance abilities during walking in subacute stroke patients. DESIGN: Cohort study. SETTING: Inpatient rehabilitation center. PARTICIPANTS: Ambulatory subjects (N=28) at a maximum of 6 months after stroke participated in this study. One direct observer and 2 video observers rated the FGA. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Performance of the FGA was video recorded and directly rated. For testing concurrent validity of the FGA, subjects also completed testing in the Berg Balance Scale, fast walking speed, the Functional Ambulatory Category, the Rivermead Mobility Index, and the Barthel Index. Intrarater reliability, interrater reliability, and concurrent validity of the FGA were analyzed. RESULTS: Intrarater (intraclass correlation coefficient=.97) and interrater reliability (intraclass correlation coefficient=.94) were almost perfect for total scores. Reliability of single items varied between substantial and almost perfect values. Analysis revealed significant correlations between the FGA and other measures of gait and balance functions between Spearman rho values of .71 and .93. The FGA differs significantly between levels of gait ability (Functional Ambulatory Category) (P< or =.01). CONCLUSIONS: Almost perfect intrarater and interrater reliability for total FGA scores and good concurrent validity were shown in this study. Therefore, the FGA (German version) can be used as a reliable and valid tool to assess functional gait performance of patients in subacute stages after stroke.
机译:目的:研究功能性步态评估(FGA)(德语版)在亚急性中风患者步行过程中平衡能力的有效性和可靠性。设计:队列研究。地点:住院康复中心。参与者:脑卒中后最多6个月的非卧床受试者(N = 28)参加了本研究。 FGA由1位直接观察员和2位视频观察员评定。干预措施:不适用。主要观察指标:对FGA的性能进行录像并直接进行评分。为了测试FGA的并发有效性,受试者还完成了Berg平衡量表,快速步行速度,功能性门诊类别,Rivermead流动性指数和Barthel指数的测试。分析了FGA的内部信度,间信度和并发有效性。结果:Intrarater(类内相关系数= 0.97)和interter可靠性(类内相关系数= 0.94)对于总分几乎是完美的。单个项目的可靠性在实质值和几乎完美值之间变化。分析显示,FGA与步态的其他度量之间的显着相关性,以及Spearman rho值介于.71和.93之间的平衡功能。 FGA在步态能力水平(功能性门诊类别)之间存在显着差异(P <或= .01)。结论:本研究显示总FGA评分的近乎完美的评分者和间信度和良好的并发效度。因此,FGA(德语版)可以用作评估卒中后亚急性期患者步态表现的可靠且有效的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号