A respiratory ozone analyzer optimized for high resolution and swift dynamic response during exercise conditions.

机译:经过优化的呼吸臭氧分析仪,可在运动条件下实现高分辨率和快速的动态响应。

获取原文
获取原文并翻译 | 示例

摘要

The breath-to-breath determination of total respiratory ozone (O3) uptake requires the monitoring of O3 concentration at the airway opening with an instrument that responds rapidly relative to the frequency of respiration. Originally, the authors developed an analyzer that used the homogeneous chemiluminescent reaction of O3 with 2-methyl-2-butene, but it was suitable only for monitoring O3 during quiet breathing and light exercise (Ben-Jebria and Ultman, Rev Sci Instrum 1989; 60:3004-11, and Ben-Jebria et al., Rev Sci Instrum 1990; 61:3435-39). The improvement of performance characteristics of the aforementioned analyzer enabled the authors to use the newly constructed and self-contained instrument, which used ethylene as the reactant gas, for respiratory O3 monitoring during moderate-to-heavy exercise. Operating at a reaction chamber pressure of 350 torr, an ethylene/sample flow ratio of 4:1, and a sampling flow of 0.6 lpm, the authors achieved an optimum analyzer performance (i.e., 10-90% step-response of 70 msec and a minimum resolution of 0.006 ppm O3). Furthermore, the new instrument did not exhibit the nonlinear calibration and the CO2 interference suffered by the original analyzer. To demonstrate the quality of the new O3 analyzer in a respiratory application (i.e., total O3 uptake), the authors measured a series of single breaths on two subjects who breathed 0.11 and 0.43 ppm O3-in-air mixtures for 15 min during rest, and during moderate and heavy exercise.
机译:从呼吸到呼吸来确定总呼吸臭氧(O3)的吸收量需要使用相对于呼吸频率快速响应的仪器监测气道开口处的O3浓度。最初,作者开发了一种分析仪,该分析仪使用O3与2-甲基-2-丁烯的均相化学发光反应,但仅适用于在安静呼吸和轻度运动期间监测O3(Ben-Jebria和Ultman,Rev Sci Instrum 1989; 60:3004-11,和Ben-Jebria等,Rev Sci Instrum 1990; 61:3435-39)。上述分析仪性能特性的改进使作者能够使用新构建的自包含式仪器,该仪器以乙烯为反应气体,用于中度到重度运动中的呼吸O3监测。在350托的反应室压力,乙烯/样品流量比为4:1和0.6 lpm的采样流量下运行,作者获得了最佳的分析仪性能(即70毫秒的10-90%阶跃响应和最低分辨率为0.006 ppm O3)。此外,新仪器没有表现出非线性校准和原始分析仪所遭受的CO2干扰。为了证明新型O3分析仪在呼吸应用中的质量(即总O3吸收量),作者对两名受试者进行了一系列单次呼吸测量,两名受试者在休息期间呼吸了0.11和0.43 ppm的O3空气混合物,呼吸时间为15分钟,以及中度和重度运动。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号