首页> 外文期刊>Applied optics >Simultaneous in situ measurement of CO, H_(2)O, and gas temperatures in a full-sized coal-fired power plant by near-infrared diode lasers
【24h】

Simultaneous in situ measurement of CO, H_(2)O, and gas temperatures in a full-sized coal-fired power plant by near-infrared diode lasers

机译:利用近红外二极管激光器同时现场测量大型火力发电厂中的CO,H_(2)O和气体温度

获取原文
获取原文并翻译 | 示例
           

摘要

We present what is to our knowledge the first near-infrared diode-laser-based absorption spectrometer that is suitable for simultaneous in situ measurement of carbon monoxide, water vapor, and temperature in the combustion chamber (20-m diameter, 13-m path length) of a 600-MW lignite-fired power plant. A fiber-coupled distributed-feedback diode-laser module at 1.56 μm served for CO detection, and a Fabry-Perot diode laser at 813 nm was used to determine H_(2)O concentrations and temperature from multiline water spectra. Despite severe light losses (transmission, <10~(-3)) and strong background radiation we achieved a resolution of 1.9×10~(-4) (1σ) fractional absorption, equivalent to 200 parts in 10~(6) by volume of CO (at 1450 K, 10~(5) Pa) with 30-s averaging time.
机译:我们提供了我们所知的第一台基于近红外二极管激光的吸收光谱仪,该光谱仪适用于同时就地测量燃烧室中的一氧化碳,水蒸气和温度(直径为20 m,路径为13 m)长度)的600兆瓦褐煤发电厂。使用1.56μm的光纤耦合分布式反馈二极管激光模块进行CO检测,并使用813 nm的Fabry-Perot二极管激光器从多线水谱确定H_(2)O浓度和温度。尽管有严重的光损失(透射,<10〜(-3))和强烈的背景辐射,我们仍实现了1.9×10〜(-4)(1σ)的部分吸收分辨率,相当于10〜(6)体积中的200份CO(在1450 K,10〜(5)Pa下)的平均时间为30秒。