A transmission differential phase-contrast microscope with a split detector is used as a readout system for a multilayered three-dimensional optical memory. The system is applicable to data recorded as refractive-index changes. The system is compact and easy to use. The three-dimensional optical transfer function for the system is derived. This shows that the spatial bandwidth of the system is the same as that of a conventional microscope with incoherent illumination but with much improved contrast. Six layers of information are recorded in a photopolymer and are read out with little cross talk and high contrast. (C) 1996 Optical Society of America [References: 14]
机译:具有分离检测器的透射差分相衬显微镜被用作多层三维光学存储器的读出系统。该系统适用于记录折射率变化的数据。该系统结构紧凑,易于使用。推导了系统的三维光学传递函数。这表明系统的空间带宽与照明不连贯的常规显微镜相同,但对比度大大提高。六层信息记录在光敏聚合物中,并且几乎没有串扰和高对比度地被读出。 (C)1996年美国眼镜学会[参考文献:14]