首页> 外文期刊>Lasers in surgery and medicine >Effect of Er:YAG, CO(2) and diode laser irradiation on surface properties of zirconia endosseous dental implants.
【24h】

Effect of Er:YAG, CO(2) and diode laser irradiation on surface properties of zirconia endosseous dental implants.

机译:Er效应:掺钕钇铝石榴石,有限公司(2)和二极管激光器辐照表面氧化锆的属性endosseous牙科植入物。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND OBJECTIVES: Zirconia implants (ZI) are becoming more popular in implant dentistry, as a result of their favorable esthetic outcome. However, little is known about the impact laser application has on this material in the course of peri-implantitis treatment. The objective of this investigation was to analyze the influence of Er:YAG, CO(2) and diode laser irradiation on polished ZI. MATERIAL AND METHODS: Yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramic disks were irradiated at different power settings with either an Er:YAG, CO(2) or diode laser. The surface of the disks was analyzed by scanning electron microscopy (SEM) and confocal 3D white light microscopy (CWLM). In addition energy-dispersive X-ray (EDX) analysis was performed on all disks. Six specimens were used for each parameter set of each laser. RESULTS: SEM analysis demonstrated that, regardless of the power settings, neither the diode laser nor the Er:YAG laser caused any visible surface alterations to ZI. The results of the CWLM were in agreement with the SEM pictures. However, Er:YAG irradiation did penetrate through the disks. At various power settings, the CO(2) treatment was characterized by material cracking and melting. The increased roughness values (from CWLM) of the ZI underlined the SEM observations. CONCLUSION: In contrast to diode and Er:YAG laser irradiation, the CO(2) laser revealed distinct surface alterations to zirconia at various laser parameters. However, the Er:YAG laser cannot be recommended for the treatment of ailing implants, as the laser beam penetrates the material. In this respect, currently, diode lasers seem to be the only laser systems offering surface preservation and safety in the treatment of peri-implantits with ZI. Laser Surg. Med. 40:223-228, 2008. (c) 2008 Wiley-Liss, Inc.
机译:背景和目的:氧化锆种植体(子)在植入牙科正变得越来越受欢迎,由于其良好的审美的结果。然而,对激光器的影响应用程序对这种材料的过程中peri-implantitis治疗。调查分析的影响呃:掺钕钇铝石榴石,(2)和二极管激光辐照抛光子。Yttria-stabilized四方氧化锆多晶体(Y-TZP)陶瓷圆盘辐射不同的电源设置一个Er:掺钕钇铝石榴石,有限公司(2)或二极管激光器。分析了扫描电子显微镜吗(SEM)和共焦三维白光显微镜(CWLM)。分析所有磁盘上执行。标本被用于每个参数组每个激光。无论电源设置,无论是二极管激光器和Er:掺钕钇铝石榴石激光器任何引起的可见表面改变子。CWLM在协议的扫描电镜照片。然而,Er:掺钕钇铝石榴石照射穿透磁盘。治疗材料开裂的特点和融化。CWLM)子强调了扫描电镜观察。结论:与二极管和Er:掺钕钇铝石榴石激光器辐照有限公司(2)激光显示不同在不同激光表面改变氧化锆参数。推荐治疗生病的植入物,随着激光束穿透材料。似乎这方面,目前,二极管激光器唯一的激光系统提供表面保护和安全的治疗peri-implantits子。40:223 - 228, 2008。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号