We describe a portable diode-laser-based sensor for NH_(3) detection using vibrational overtone absorption spectroscopy at 1.53 μm. Use of fiber-coupled optical elements makes such a trace gas sensor rugged and easy to align. On-line data acquisition and processing requiring <30 s can be performed with a laptop PC running LabVIEW software. The gas sensor was used primarily for NH_(3) concentration measurements with a sensitivity of 0.7 parts per million (signal-to-noise ratio of 3) over a two-week period in a bioreactor being developed at the NASA Johnson Space Center for water treatment technologies to support long-duration space missions. The feasibility of simultaneous, real-time measurements of NH_(3) and CO_(2) concentrations is also reported.
机译:我们描述了一种便携式的基于二极管激光的传感器,用于使用振动泛音吸收光谱在1.53μm的NH_(3)检测。光纤耦合光学元件的使用使这种痕量气体传感器坚固耐用且易于对准。可以使用运行LabVIEW软件的便携式PC进行30秒以内的在线数据采集和处理。气体传感器主要用于NH_(3)浓度测量,在NASA约翰逊航天中心为水开发的生物反应器中,在两周的时间内灵敏度为0.7百万分之一(信噪比为3)。处理技术来支持长时间的太空任务。还报告了同时实时测量NH_(3)和CO_(2)浓度的可行性。