首页> 外文期刊>Applied occupational and environmental hygiene >Comparison of five methods for fit-testing N95 filtering-facepiece respirators.
【24h】

Comparison of five methods for fit-testing N95 filtering-facepiece respirators.

机译:比较N95过滤式面罩呼吸器的五种拟合测试方法。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Five fit-testing methods (Bitrex, ambient aerosol condensation nuclei counter using the TSI PortaCount Plus, saccharin, modified ambient aerosol condensation nuclei counter using the TSI PortaCount Plus with the N95-Companion, and generated aerosol using corn oil) were evaluated for their ability to identify poorly fitting N95 filtering-facepiece respirators. Eighteen models of NIOSH-certified, N95 filtering-facepiece respirators were tested by a panel of 25 subjects using each fit-testing method. The penetration of the corn oil and the ambient aerosols through the filter media of each respirator was measured in order to adjust the corresponding generated and ambient aerosol overall fit factors, reflecting only face-seal leakage. Fit-testing results were compared to 5th percentiles of simulated workplace protection factors. Beta errors (the chance of passing a fit-test in error) ranged from 3 percent to 11 percent. Alpha errors (the chance of failing a fit-test in error) ranged from 51 percent to 84 percent. The ambient aerosol using the TSI PortaCount Plus and the generated aerosol methods identified poorly fitting respirators better than the saccharin, the Companion, and Bitrex methods. These errors rates should be considered when selecting a fit-testing method for fitting N95 filtering-facepieces. When both types of errors were combined as an assignment error, the ambient aerosol method using the TSI PortaCount Plus had the lowest percentage of wearers being assigned a poor-fitting respirator.
机译:评估了五种拟合测试方法(Bitrex,使用TSI PortaCount Plus的环境气溶胶凝结核计数器,糖精,使用TSI PortaCount Plus的N95-Companion改进的环境气溶胶凝结核计数器以及使用玉米油生成的气溶胶)的能力。以确定不合适的N95过滤式面罩呼吸器。由25位受试者组成的小组使用每种拟合测试方法对18种经NIOSH认证的N95过滤式面罩呼吸器进行了测试。测量玉米油和周围气雾剂穿过每个呼吸器的过滤介质的渗透,以调节相应的生成的和周围气雾剂的总体贴合系数,仅反映面密封泄漏。将拟合测试结果与模拟工作场所保护因素的第5个百分位数进行比较。 Beta错误(通过错误的拟合检验的机会)范围从3%到11%。 Alpha错误(在错误中导致拟合测试失败的机会)的范围从51%到84%。使用TSI PortaCount Plus的环境气雾剂和生成的气雾剂方法比糖精,伴侣和Bitrex方法更好地确定了佩戴不当的呼吸器。选择适合N95过滤面罩的拟合测试方法时,应考虑这些错误率。当将两种类型的错误都归为分配错误时,使用TSI PortaCount Plus的环境气雾法为佩戴者分配的不合适的呼吸器的比例最低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号