The aim of the study was to assess the use of 3M porous polymer extraction discs (3M Empore sorbent filters) for detection of chemical permeation of protective clothing. Analysis of some commonly used solvents on 3M Empore sorbent filters was performed for methanol, acetone, trichloroethylene (TriCE), and toluene by solvent desorption and gas chromatography. All solvents exhibited >98 percent adsorption on the filters at a spiking level of 1.8 microL for each solvent. Solvent recovery for the system was calculated for each solvent, ranging from 72-94 percent (RSD < or = 4.0%) for all solvents over the spiking range 0.2-1.8 microL. The modified ASTM F739 method was used to determine breakthrough times for five protective glove materials (polyvinyl chloride, natural rubber, polymerized alkene, nitrile, and nitrile butyl rubber) using the model solvents as test chemicals. Breakthrough times for each type of protective glove were determined, and found to range from 36 s to 9 min for acetone, from 142 s to 52 min for methanol, from 18 s to 12 min for TriCE, and from 32 s to 28 min for toluene. The quantitative mass of the solvents on the filters at the time of breakthrough detection ranged from 150-159, 157-166, 570-581, and 371-382 microg/cm2 for acetone, methanol, TriCE, and toluene, respectively. The sorbent filter should find utility in collecting chemical permeation samples through protective gloves in both laboratory and field studies for quantitative analysis.
机译:该研究的目的是评估使用3M多孔聚合物萃取盘(3M Empore吸附剂过滤器)检测防护服的化学渗透性。通过溶剂解吸和气相色谱法对3M Empore吸附剂过滤器上的一些常用溶剂进行了甲醇,丙酮,三氯乙烯(TriCE)和甲苯的分析。对于每种溶剂,所有溶剂在过滤器上均表现出> 98%的吸附,峰值浓度为1.8微升。对于每种溶剂,计算系统的溶剂回收率,对于加标范围为0.2-1.8 microL的所有溶剂,回收率为72-94%(RSD <或= 4.0%)。使用改进的ASTM F739方法,使用模型溶剂作为测试化学品,确定五种防护手套材料(聚氯乙烯,天然橡胶,聚合烯烃,丁腈和丁腈橡胶)的穿透时间。确定每种类型的防护手套的突围时间,对于丙酮而言为36 s至9分钟,对于甲醇而言为142 s至52分钟,对于TriCE为18 s至12分钟,对于TriCE为32 s至28分钟。甲苯。突破检测时,过滤器上的丙酮,甲醇,TriCE和甲苯的定量质量分别为150-159、157-166、570-581和371-382 microg / cm2。吸附剂过滤器应可用于实验室和现场研究中通过防护手套收集化学渗透样品进行定量分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号