首页> 外文期刊>Applied occupational and environmental hygiene >Capability of respirator wearers to detect aerosolized qualitative fit test agents (sweetener and Bitrex) with known fixed leaks.
【24h】

Capability of respirator wearers to detect aerosolized qualitative fit test agents (sweetener and Bitrex) with known fixed leaks.

机译:呼吸器佩戴者具有检测已知固定泄漏的气溶胶定性测试剂(甜味剂和Bitrex)的能力。

获取原文
获取原文并翻译 | 示例
           

摘要

This study was designed to evaluate and compare the ability of respirator wearers to detect qualitative respirator fit test agents (saccharin and Bitrex) when the respirators were modified to include fixed size leaks. In recent years the number of persons who require fit testing has increased, partly in response to the needs of health care workers with potential exposure to infectious bio-aerosols. Many health care providers have chosen qualitative respirator fit testing using saccharin and/or Bitrex for a variety of reasons, including (but not limited to) low initial equipment cost. Respirators were modified to include a mid-line sampling probe between the nose and mouth for quantitative fit testing with a TSI PortaCount. A second modification included the introduction of a shortened 14-gauge intravenous catheter at the bridge of the nose. The fixed leak was designed to produce fit factors < 100 when unplugged, with an average fit factor of 67 among 26 respirator wearers. A complete fit test was not performed, because one purpose of this study was to determine the ability of respirator wearers to detect a known fixed leak during a single normal breathing exercise, without introducing unknown and potentially variable size leaks. Sensitivity threshold screening included a placebo and requirement to correctly characterize the taste of the agent used. Quantitative fit factors without leaks ranged from 96 to > 20,000 and 22 to 160 with the leak present. Twenty four of 26 subjects had fit factors < 100 (92%) when fixed leaks were induced. All subjects correctly detected Bitrex with fixed leaks (sensitivity = 100%). Nine of 26 subjects (35%) were unable to detect saccharin in the presence of a known fixed leak even though the average fit factor for these subjects was 77. When the two subjects with fit factors > 100 were excluded, only 16 of 24 respirator wearers were able to detect saccharin with fixed leaks (sensitivity = 67%). There were several important aspects of our study design worth noting, including the introduction of a placebo during sensitivity threshold testing, limiting the subject response time to a single maneuver, using a higher concentration of Bitrex than commercially available, and requiring the subjects to correctly characterize the taste of the qualitative test agent. In conclusion, leak detection was correctly identified with Bitrex, but not saccharin.
机译:本研究旨在评估和比较佩戴防毒面具的呼吸器佩戴者检测出定性防毒面具合适测试剂(糖精和Bitrex)的能力,以适应固定尺寸的泄漏。近年来,需要进行体格检查的人数有所增加,部分是为了响应可能接触传染性生物气溶胶的医护人员的需求。许多医疗保健提供者出于多种原因选择使用糖精和/或Bitrex进行定性呼吸器合身性测试,包括(但不限于)较低的初始设备成本。呼吸器经过修改,在鼻和嘴之间包括一个中线采样探针,用于使用TSI PortaCount进行定量拟合测试。第二种修改包括在鼻梁处插入一个14号短的静脉内导管。固定的泄漏设计为在拔下插头时产生小于100的适配系数,在26个呼吸器佩戴者中平均适配系数为67。没有进行完全合适的测试,因为该研究的目的是确定呼吸器佩戴者在一次正常的呼吸运动中检测到已知的固定泄漏的能力,而不会引起未知的和潜在的可变大小的泄漏。敏感性阈值筛查包括安慰剂和正确表征所用药物味道的要求。没有泄漏的定量拟合系数范围从96到> 20,000,有泄漏的范围从22到160。当引起固定性漏气时,26名受试者中的24名具有<100(92%)的拟合系数。所有受试者均正确检测到Bitrex,且泄漏固定(灵敏度= 100%)。 26名受试者中有9名(35%)在存在已知的固定泄漏的情况下无法检测糖精,即使这些受试者的平均拟合因子为77。如果排除了两个拟合因子> 100的受试者,则24台呼吸器中只有16例佩戴者能够以固定的泄漏量检测糖精(灵敏度= 67%)。我们的研究设计有几个重要方面值得注意,包括在敏感性阈值测试期间引入安慰剂,将受试者的反应时间限制为一次操作,使用比市售浓度更高的Bitrex以及要求受试者正确表征定性测试剂的味道。总之,可以使用Bitrex正确识别泄漏检测,但不能正确识别糖精。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号