首页> 外文期刊>Applied occupational and environmental hygiene >Electrostatic respirator filter media: filter efficiency and most penetrating particle size effects.
【24h】

Electrostatic respirator filter media: filter efficiency and most penetrating particle size effects.

机译:静电呼吸器过滤介质:过滤效率高,且穿透力最大。

获取原文
获取原文并翻译 | 示例
           

摘要

New electrostatic filter media has been developed for use in 42 CFR 84 negative pressure particulate respirator filters. This respirator filter media was not available for evaluation prior to the change from 30 CFR 11 to 42 CFR 84. Thus, characterization of this filter media is warranted. In this study, the new 42 CFR 84 electrostatic respirator filters were investigated with respect to filter penetration and most penetrating particle size. Three different models of N95 filters, along with one model each of the N99, R95, and P100 class filters were used in this study. First, three of each filter were loaded with a sodium chloride (NaCl) aerosol, and three of each filter were loaded with a dioctyl phthalate (DOP) aerosol to obtain normal background penetration results for each filter. Then, two new filters of each type were dipped in isopropanol for 15 seconds and allowed to dry. This isopropanol dip should reduce or eliminate any electrostatic charge on the fibers of each filter, as reported in the technical literature. These dipped filters, along with controls of each filter type, were tested on a TSI 8160 filter tester to determine the most penetrating particle size. These same filters were then tested against a NaCl aerosol to get final penetration values. Electret filters rely heavily on their electrostatic charge to provide adequate filter efficiencies, and correlations between penetration and a filter's electrostatic characteristics are found in the technical literature. In all six of the filter models tested, filter penetration values increased considerably and the most penetrating particle size noticeably shifted toward larger particles. These results are important in better understanding how these new filter materials perform under various conditions, and they indicate the need for additional research to define environmental conditions that may affect electrostatic filter efficiency.
机译:已开发出新的静电过滤介质,可用于42 CFR 84负压颗粒物呼吸器过滤器。在从30 CFR 11更改为42 CFR 84之前,该呼吸器滤材不可用于评估。因此,必须对这种滤材进行表征。在这项研究中,对新型42 CFR 84静电呼吸器过滤器进行了研究,以了解过滤器的渗透性和最穿透的颗粒尺寸。在这项研究中,使用了三种不同型号的N95过滤器,以及一种型号的N99,R95和P100类过滤器。首先,每个过滤器中的三个装有氯化钠(NaCl)气雾剂,每个过滤器中的三个装有邻苯二甲酸二辛酯(DOP)气雾剂,以获得每个过滤器的正常背景渗透结果。然后,将每种类型的两个新过滤器浸入异丙醇中15秒钟,然后干燥。如技术文献中所报道的,这种异丙醇浸渍应减少或消除每个过滤器纤维上的任何静电荷。在TSI 8160过滤器测试仪上对这些浸入式过滤器以及每种过滤器类型的控件进行了测试,以确定最穿透的颗粒尺寸。然后将这些相同的过滤器针对NaCl气雾剂进行测试,以获得最终的渗透值。驻极体过滤器在很大程度上依靠其静电荷来提供足够的过滤效率,并且在技术文献中发现了渗透率与过滤器的静电特性之间的相关性。在所测试的所有六个过滤器模型中,过滤器穿透值均显着增加,并且最穿透的颗粒尺寸明显移向较大的颗粒。这些结果对于更好地理解这些新型过滤器材料在各种条件下的性能非常重要,并且它们表明需要进行进一步的研究来定义可能影响静电过滤器效率的环境条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号