首页> 外文期刊>Archives of disease in childhood >Improvement of nebulised antibiotic delivery in cystic fibrosis.
【24h】

Improvement of nebulised antibiotic delivery in cystic fibrosis.

机译:改善囊状纤维化中雾化抗生素的递送。

获取原文
获取原文并翻译 | 示例
       

摘要

AIM: To investigate deposition patterns and to assess the delivery rate of two nebuliser systems in children with cystic fibrosis (CF). METHODS: Thirty three children with CF on regular treatment with nebulised antibiotics had radioisotope scans performed using technetium-99m labelled aerosol antibiotic generated by a Ventstream nebuliser (median mass diameter (MMD), 3.3 microm; delivery rate, 0. 075 ml/min) under conditions similar to their routine home practice. The inhomogeneity of the images was scored on a 1-10 rating scale (a low score indicating even distribution of the antibiotic), and stomach deposition was measured as a percentage of overall deposition. Twenty patients had a repeat scan using an Optimist nebuliser (MMD, 1.8 microm; delivery rate, 0.02 ml/min). RESULTS: The mean inhomogeneity scores were 5.4 in the Ventstream group and 3. 5 in the Optimist group. Mean stomach deposition was 17.3% in the 33 patients using the Ventstream nebuliser. There was an inverse relation between height and stomach deposition (r = 0.69). In the 20 patients who had both nebulisers, the mean percentages of stomach deposition for the Ventstream and Optimist nebulisers were 11.8% and 1.6%, respectively. The Ventstream nebuliser delivered antibiotic at an average 2.8 times faster rate than the Optimist nebuliser. IMPLICATIONS: A smaller particle size results in a more homogenous distribution of the antibiotic in the lungs with decreased stomach deposition. This should not be seen as a recommendation to use the Optimist nebuliser because more antibiotic was delivered to most parts of the lung with the Ventstream because of its increased delivery rate.
机译:目的:调查沉积模式并评估两个雾化系统在囊性纤维化(CF)患儿中的分娩率。方法:33例接受常规雾化抗生素治疗的CF儿童,使用Ventstream雾化器生成的tech 99m标记气溶胶抗生素进行放射性同位素扫描(中位直径(MMD)为3.3微米;分娩率为0. 075毫升/分钟)在类似于他们日常家庭实践的条件下。图像的不均匀性以1-10的等级评分(低分表示抗生素均匀分布),并以总沉积的百分比测量胃部沉积。 20名患者使用Optimist雾化器进行了重复扫描(MMD,1.8微米;分娩速度,0.02毫升/分钟)。结果:Ventstream组的平均不均匀性得分为5.4,而Optimist组的平均得分为3. 5。使用Ventstream雾化器的33例患者的平均胃部沉积为17.3%。身高与胃沉积之间存在反比关系(r = 0.69)。在同时使用两种雾化器的20例患者中,Ventstream雾化器和Optimist雾化器的胃部沉积平均百分率分别为11.8%和1.6%。 Ventstream雾化器的抗生素释放速度比Optimist雾化器平均快2.8倍。含义:较小的粒径导致抗生素在肺中分布更均匀,胃部沉积减少。这不应被视为使用Optimist雾化器的建议,因为随着Ventstream的增加的输送速度,它会将更多的抗生素输送到肺的大部分部位。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号