Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature.

机译:测量角膜的生物力学属性眼响应分析仪及其协会与眼压中央角膜曲率。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The aim of this study was to investigate the biomechanical properties of the cornea and their association with intraocular pressure (IOP), central corneal thickness (CCT) and the central corneal radius of curvature (Rc). METHODS: Eighty-three eyes were divided into two groups. The biomechanical properties of the cornea were measured in 63 normal eyes and in 20 post-laser in situ keratomileusis (LASIK) eyes. The IOP, corneal hysteresis (CH) and corneal resistance factor (CRF) were measured by the Ocular Response Analyzer (ORA). The Rc and CCT were measured using the corneal topographer Medmont E-300 and the Tomey SP-100 Handy ultrasonic pachymeter. Other parameters measured by the ORA, such as TimeIn and TimeOut, were also studied. RESULTS: A mean corneal hysteresis of 10.8 mmHg and CRF of 10.6 mmHg were recorded for the normal eyes. There was no significant association with central curvature. All parameters measured by the ORA showed a significant correlation with the CCT, except for the corneal-compensated intraocular pressure (IOPcc). Both IOPs measured by the ORA had the same values for the mean CH and CRF. For the post-LASIK eyes, the CH and CRF were lower than in the normal non-operated eyes. The TimeIn and the TimeOut also presented lower values for the post-LASIK eyes, suggesting that additional data can be obtained with the ORA measurements. CONCLUSIONS: The results of this study indicate that there is no correlation between the parameters measured with the Ocular Response Analyzer and central corneal radius of curvature. Some of the biomechanical properties of the cornea studied were found to differ in the normal eyes compared to the post-LASIK eyes.
机译:背景:本研究的目的是调查的生物力学特性与人工角膜和他们联系压(IOP),中央角膜厚度(CCT)和中央角膜曲率半径(Rc)。方法:八十三只眼睛被分成两组组。63年角膜测量正常的眼睛和20在张大时post-laser (LASIK)的眼睛。眼压、角膜滞后(CH)和角膜阻力系数(CRF)来衡量眼部反应分析仪(奥拉)。测量角膜地形学者吗Medmont e - 300和Tomey sp - 100方便超声波测厚计。奥拉,超时,世代都会面临着这样如时刻也研究。10.8毫米汞柱和CRF 10.6毫米汞柱都被记录下来正常的眼睛。与中央曲率。奥拉显示测量的参数显著相关的有条件现金援助,除了的corneal-compensated眼压(IOPcc)。值意味着CH和CRF相同。post-LASIK眼睛,CH和CRF低于在正常非手术的眼睛。超时也呈现较低的值post-LASIK眼睛,这表明额外的数据可以获得与奥拉测量。结论:这项研究的结果表明这没有关系参数测量与眼部反应分析器和中央角膜曲率半径。的生物力学特性正常的角膜研究发现不同眼睛比post-LASIK眼睛。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号