首页> 外文期刊>Clinical & experimental optometry: journal of the Australian Optometrical Association >Ocular preference following implantation of aspheric and spherical intraocular lenses; an intra-individual comparison.
【24h】

Ocular preference following implantation of aspheric and spherical intraocular lenses; an intra-individual comparison.

机译:眼植入后的偏好非球面与球面人工晶体;自身内在的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: recently, intraocular lenses (IOLs) that possess an aspheric design, compensating for the spherical aberration (SA) of the cornea, have been developed. We designed this study to compare a group of patients who had undergone bilateral cataract surgery and had received one spherical IOL and one aspheric IOL, to assess their ocular preference. METHODS: patients were recruited from those who had undergone bilateral cataract surgery during the preceding six months (32 patients). Types of aspheric IOLs, which were used included: Tecnis ZA9003, AcrysofIQ SN60WF and Akreos Adapt AO. Contrast acuity was measured using a CSV-1000CVA instrument and spherical aberration (SA) was measured using a Zywave aberrometer. Patients also answered a brief questionnaire, designed to determine whether they could detect any difference between their spherical and aspheric IOLs and whether they had an ocular preference. RESULTS: no differences were found between spherical and aspheric IOLs in contrast acuity. Total ocular spherical aberration was greater among eyes with spherical IOLs compared with aspheric IOLs (t = 6.67; p < 0.0001). Patients' ocular preference was unrelated to the presence of an aspheric IOL or the amount of spherical aberration, but was associated with the level of ametropia and visual acuity. CONCLUSIONS: we were unable to find any impact on a patient's subjective visual quality from a reduction of spherical aberration by the presence of an aspheric IOL. Ocular preference was determined by level of visual acuity and degree of ametropia post-operatively.
机译:目的:最近,人工晶状体(人工晶体)拥有一个非球面设计,补偿球面像差(SA)的角膜被开发出来。一群病人经历了两国白内障手术,收到了一个球形人工晶体和一个非球面人工晶体,来评估他们的眼偏好。那些经历了双边白内障手术前6个月期间(32病人)。包括:使用Tecnis ZA9003, AcrysofIQ SN60WF和AO Akreos适应。使用csv - 1000 cva的仪器和球形使用Zywave畸变(SA)测量象差计。问卷调查,以确定他们是否设计他们可能发现任何区别球面和非球面人工晶体和他们是否有一个眼的偏好。球面和非球面人工晶体之间被发现对比灵敏度。像差与球面之间的大眼睛人工晶体与非球面人工晶体(t = 6.67;0.0001)。与一个非球面人工晶体的存在的球面像差,但与屈光异常的程度和视觉有关敏度。对病人的主观视觉质量的影响从减少球面像差非球面人工晶体的存在。是由水平的视力和程度的屈光异常结束。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号