A point-of-care diagnostics logic detector based on glucose oxidase immobilized lanthanide functionalized metal-organic frameworks

机译:基于现场即时诊断逻辑探测器在葡萄糖氧化酶固定镧系元素功能化有机框架

获取原文
获取原文并翻译 | 示例

摘要

In this work, a novel lanthanide functionalized metal organic framework enzyme (L-MOF-enzyme) composite has been first prepared via a surface attachment strategy between Eu3+@UMOF and glucose oxidase (GOx). Here, the Eu3+@UMOF can be used as a support for GOx immobilization and also a responsive fluorescent center towards glucose (Glu). The resulting material not only exhibits fascinating luminescence properties based on the D-5(0) -> F-7(2) transition of Eu3+ and the catalytic performance of enzymes, but also some advantages of MOF-enzyme composites, including better stability, and great fluorescence selectivity and sensitivity towards Glu (detection limit = 0.2 mu M). Besides, the composite exhibited an excellent selectivity and sensitivity towards Glu in serum and urine under room temperature and neutral conditions, which breaks the limitation of specific catalytic conditions of enzymes. Taking all the advantages of the L-MOF-enzyme composite, a point-of care (POC) diagnostics logic detector which can be used for the fluorescence detection of Glu in urine is designed. From the three outputs of the logic detector (L, M and H), we can intuitively realize the self-diagnosis of the three ranges of Glu concentrations that act as the inputs of the detector (0.1 mu M-10 mu M, 10 mu M-10 mM, >10 mM) by the naked eye. The logic detector allows us, especially diabetics, to instantly detect glucose levels in the urine without going to the hospital for complicated inspections. This is the first attempt using L-MOFs combined with GOx to construct a POC diagnostics logic detector for fluorescence detection of Glu.
机译:在这项工作中,小说镧系元素官能团金属有机框架酶(L-MOF-enzyme)通过表面复合已经第一次准备欧盟三国之间的依恋策略+ @UMOF和葡萄糖氧化酶(气态氧)。气态氧固定和支持对葡萄糖响应荧光中心(Glu)。迷人的发光特性的基础上D-5 (0) - > F-7欧盟三国+和(2)过渡酶的催化性能,但也有一些MOF-enzyme复合材料的优势,包括更好的稳定性,和伟大的荧光对Glu选择性和灵敏度(检测极限= 0.2μM)。此外,复合材料表现出一个优秀的选择性和对在血清和尿液Glu敏感性室温和中性条件下,打破限制特定的催化酶的条件。L-MOF-enzyme复合的的护理(POC)诊断逻辑探测器可以用于Glu的荧光检测尿液是设计。逻辑探测器(L, M和H),我们可以直观的实现的三个范围的自我诊断Glu浓度作为输入的探测器(0.1μ辆μM, 10μ打光最后一毫米,> 10通过肉眼毫米)。我们,特别是糖尿病患者,即时检测没有去看尿液中葡萄糖水平复杂的医院检查。第一次尝试使用L-MOFs和气态氧结合构造一个POC诊断逻辑探测器Glu的荧光检测。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号