Penile implants are used for erectile dysfunction (ED). Their main disadvantage is that the cavernous tissue is destroyed and replaced by fibrous so that implant replacement is difficult and the penis loses its erectile function permanently. This paper describes a novel prosthesis which is hollow and fenestrated to preserve, as much as possible, the cavernous tissue. The fenestrated implant was used in 18 men with ED, while the solid Small-Carrion implants were used in 14 impotent men who matched the 18 men in age and cause of impotence and acted as controls. Routine erectile function tests suggested that the ED was neurogenic. The fenestrated prosthesis was a hollow semisolid silicone rod with multiple openings (2-3 mm in diameter) along its whole length. The mean follow up of the patients was 43 +/- 12 SD months. No complications were encountered. Vaginal penetration was successful in the fenestrated and Small-Carrion implant groups. A total of 14/18 patients of the fenestrated prosthesis group experienced spontaneous erections upon sexual arousal, while none of the Small-Carrion prosthesis group did. During the sexual act the penis became tumescent in the patients of the former group but not in those of the latter. It is suggested that the residual cavernous tissue after insertion of the hollow fenestrated implant regenerates through the fenestrae into the implant lumen. This might explain the spontaneous erections upon sexual arousal and the tumescence during the sexual act, but this hypothesis remains to be proved histologically.
机译:阴茎植入物用于勃起功能障碍(ED)。它们的主要缺点是海绵状组织被破坏并被纤维所替代,因此植入物的置换很困难,并且阴茎永久失去勃起功能。本文介绍了一种新颖的假体,该假体是空心的且有孔,以尽可能保留海绵状组织。开窗开孔的植入物用于18例ED患者,而坚固的小腐肉植入物用于14例无力的男性,与年龄和阳cause原因匹配的18名男性用作对照。常规勃起功能测试表明ED是神经源性的。有孔的假体是空心的半固态硅胶棒,在其整个长度上具有多个开口(直径为2-3 mm)。患者的平均随访时间为43 +/- 12个SD月。没有遇到并发症。在有孔的和小腐肉植入物组中,阴道渗透是成功的。开窗假体组中共有14/18例患者在性唤起时自发勃起,而小腐肉假体组中无一例。在性行为期间,前一组患者的阴茎变得肿胀,而后者则没有。建议在将空心有孔的植入物插入后,残留的海绵状组织通过窗孔再生到植入物内腔中。这可能解释了性唤起时的自发性勃起和性行为时的肿胀,但是这一假说尚需在组织学上得到证实。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号