首页> 外文期刊>Aquacultural Engineering: An International Journal >Performance evaluation of an inclined belt filter using coagulation/flocculation aids for the removal of suspended solids and phosphorus from microscreen backwash effluent.
【24h】

Performance evaluation of an inclined belt filter using coagulation/flocculation aids for the removal of suspended solids and phosphorus from microscreen backwash effluent.

机译:使用凝结/絮凝助剂去除微筛反洗流出物中的悬浮固体和磷的倾斜带式过滤器的性能评估。

获取原文
获取原文并翻译 | 示例
           

摘要

As environmental regulations become more stringent, environmentally sound waste management and disposal practices are increasingly more important in all types of aquaculture. In many recirculation systems, microscreen filters are used to remove and concentrate the suspended solids from the process water, because they require minimal labour and floor space and can treat large flow rates of water with little head loss. These microscreen filters generate a separate solids waste stream that can be further concentrated to reduce the quantity and improve the quality of discharge water. A Belt Filter System, Hydrotech Model HBF537-1H, from Waste Management Technologies Inc., Baton Rouge, LA, USA was evaluated for rapid thickening of sludge from the backwash water of a microscreen filter. When used in conjunction with coagulation/flocculation aids, significant reduction of suspended solid and phosphorus are possible. Testing of the system was conducted using the backwash effluent of a microscreen filter that treated water discharged from several large-scale recirculating aquaculture production systems growing artic char and trout. The system was tested using only alum as the coagulant aid, using only a commercially available polymer as the flocculation aid and the two coagulation/flocculation aids in combination. Alum alone was moderately efficient in removing solids (82%), but was very efficient in sequestering reactive phosphorus (96%), with effluent concentrations less than 0.07 mg/L-P at the highest alum dosage tested, 100 mg/L. Several commercially available polymers used alone and at relatively low dosages (15 mg/L) were very effective in removing suspended solids, with a removal rate averaging 96% and with an effluent TSS concentration of less than 30 mg/L. The polymers were not as efficient as alum in removing reactive phosphorus, with a removal rate of approximately 40%. At the optimum combined dosage of alum (mg/L) and polymer (mg/L), the Inclined Belt Filter System increased the dry matter content of the sludge to approximately 13% solids, and reduced both the suspended solids and reactive phosphorus concentration of the effluent by 95 and 80%, respectively. The combination of coagulation/flocculation aids and the inclined belt filter show excellent potential to greatly reduce the volume of solids generated, and significantly reduce the concentration of suspended solids and phosphorus in discharged effluents. By eliminating the need for settling tanks or ponds, the leaching of nutrients (phosphorus, nitrogen) is minimized and the dewatered sludge is in a form for easy transport, storage, or disposal..
机译:随着环境法规变得更加严格,无害环境的废物管理和处置方法在所有类型的水产养殖中变得越来越重要。在许多再循环系统中,微筛滤器用于从工艺用水中去除并浓缩悬浮的固体,因为它们需要的劳动量和占地面积最小,并且可以处理大流量的水而几乎没有水头损失。这些微滤过滤器产生单独的固体废物流,可以进一步浓缩以减少数量并提高排放水的质量。对来自美国路易斯安那州巴吞鲁日的废物管理技术公司的Hydrotech Model HBF537-1H型带式过滤器系统进行了评估,以从微筛滤器的反冲洗水中快速浓缩污泥。当与凝结/絮凝助剂结合使用时,可能会大大减少悬浮的固体和磷。该系统的测试是使用微滤器的反冲洗流出物进行处理的,该滤器处理了从几个大型循环水产养殖生产系统中生长出的焦炭和鳟鱼排出的水。仅使用明矾作为凝结助剂,仅使用可商购的聚合物作为絮凝助剂和两种凝结/絮凝助剂结合使用对系统进行测试。仅明矾对去除固体的效率中等(82%),但对螯合活性磷非常有效(96%),在测试的最高明矾剂量(100 mg / L)下,废水浓度小于0.07 mg / L-P。几种单独使用的且相对较低剂量(15 mg / L)的市售聚合物在去除悬浮固体方面非常有效,去除率平均为96%,流出物TSS浓度低于30 mg / L。该聚合物在去除活性磷方面不如明矾有效,去除率约为40%。在明矾(mg / L)和聚合物(mg / L)的最佳组合剂量下,倾斜带式过滤器系统将污泥的干物质含量提高到约13%的固体含量,并降低了悬浮固体和活性磷的浓度。废水分别占95%和80%。凝结/絮凝助剂与倾斜带式过滤器的组合显示出极好的潜力,可以大大减少所产生的固体量,并显着降低排出的废水中悬浮固体和磷的浓度。通过消除对沉淀池或池的需要,营养素(磷,氮)的淋失得以最小化,脱水污泥的形式易于运输,存储或处置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号