The magnetic resonance-guided focused ultrasound (MRgFUS) system uses MR imaging for real-time aiming of thermal ablation of bone and soft tissue tumors. Past clinical studies showed no increase in fracture rate after MRgFUS treatment. The purpose of this study was to determine the effect of MRgFUS treatment on mechanical properties of bone and correlate the effect to histological findings of treated bone. Four fully grown mini-pigs were treated by MRgFUS. Six consecutive right normal ribs were treated in each animal, and the left corresponding ribs served as controls. The animals were sacrificed at pre-set intervals (0, 2, 6 and 12weeks after treatment), and the treated and control bones were extracted. Mechanical properties of each bone were examined using three points bending studies for comparing treated bones to the corresponding controls. Histologic properties using Masson and hematoxylin-eosin stains were also compared. The ratio between treated and control biomechanical properties showed reduction in bone biomechanical properties at 6weeks post-MRgFUS treatment. The mean±SD yield load ratio and maximum ratios were 0.69±0.11 and 0.71±0.13, respectively (both p=0.031). These findings showed some recovery trend at 12weeks after treatment. Histological analysis showed a reduction in mean osteon size at 2weeks after treatment (0.58×10-3±0.1×10-3mm and 0.16×10-3±0.017×10-3mm) in control vs. treated bones, respectively (p=0.005). Treatment with the MRgFUS system resulted in a ~30% reduction in mechanical strength at 6weeks post-treatment. The reduction showed a reversible trend, with a 25%-20% decrease in strength at 12weeks post-treatment. ?MRgFUS causes a transient decrease in bone strength with nadir at 6weeks and recovery by 3months post-treatment.
机译:磁共振引导聚焦超声(MRgFUS)系统使用MR成像实时瞄准骨和软组织肿瘤的热消融。过去的临床研究表明,MRgFUS治疗后骨折率没有增加。这项研究的目的是确定MRgFUS治疗对骨骼力学性能的影响,并将其与治疗骨骼的组织学发现相关联。 MRgFUS处理了四只完全生长的小型猪。在每只动物中治疗了六个连续的右正常肋骨,并且左对应的肋骨用作对照。以预定的时间间隔(治疗后0、2、6和12周)处死动物,并取出治疗和对照的骨头。使用三点弯曲研究检查了每个骨骼的机械性能,以将处理过的骨骼与相应的对照进行比较。还比较了使用Masson和苏木精-伊红染色的组织学性质。在MRgFUS治疗后6周,已处理生物力学性能与对照生物力学性能之间的比率显示出骨生物力学性能降低。平均±SD屈服负荷比和最大比分别为0.69±0.11和0.71±0.13(均p = 0.031)。这些发现显示治疗后12周有一定的恢复趋势。组织学分析显示,与治疗后的骨骼相比,治疗后2周平均骨大小减小(0.58×10-3±0.1×10-3mm和0.16×10-3±0.017×10-3mm)(p = 0.005) )。使用MRgFUS系统进行的治疗导致治疗后6周的机械强度降低了约30%。降低显示出可逆的趋势,治疗后12周强度降低25%-20%。 ?MRgFUS导致骨骼强度在6周时出现最低点的短暂降低,并在治疗后3个月恢复。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号