On-line coupling of LC and ICP-MS has been used for fractionation and detection of species of Cu, Fe,I,Se and Zn in human serum.It has been shown that anion exchange chromatography provided better separation capability (both intra-and inter-element) than size-exclusion chromatography.The mobile phases for ion exchange chromatography consisted of Tris-HNO_3 buffer and ammonium salt (nitrate,acetate or formate).Formate was found to be the best mobile phase counter ion,enabling good chromatographic separation,and is acceptable for mass spectrometry too.The quantitative evaluation of element concentrations adhering to individual fractions was performed by the peak area normalization method.The repeatability of results ranged from 3 to 15% (depending on the element concentration level) and represented the main part of the result uncertainty.The accuracy of Cu and Zn fraction determinations was confirmed by comparison with the isotope dilution technique.
机译:LC和ICP-MS的在线耦合已用于分离和检测人血清中Cu,Fe,I,Se和Zn的种类,已证明阴离子交换色谱法提供了更好的分离能力离子交换色谱的流动相由Tris-HNO_3缓冲液和铵盐(硝酸根,乙酸根或甲酸根)组成。甲酰胺被认为是最好的流动相抗衡离子,可实现良好的色谱分离通过峰面积归一化方法对附着在各个组分上的元素浓度进行定量评估。结果的可重复性范围为3%至15%(取决于元素浓度水平),代表了主要通过与同位素稀释技术的比较,证实了铜和锌含量测定的准确性。