首页> 外文期刊>Applied Organometallic Chemistry >Ion chromatography-inductively coupled plasma mass spectrometry determination of arsenic species in marine samples
【24h】

Ion chromatography-inductively coupled plasma mass spectrometry determination of arsenic species in marine samples

机译:离子色谱-电感耦合等离子体质谱法测定海洋样品中的砷

获取原文
获取原文并翻译 | 示例
           

摘要

Arsenic speciation analysis in marine samples was performed using ion chromatography (IC) with inductively coupled plasma mass spectrometry (ICP-MS) detection.The separation of eight arsenic species,viz.arsenite,monomethyl arsonic acid,dimethylarsinic acid,arsenate,arsenobetaine,tetramethylarsine oxide,arsenocholine and tetramethylarsonium ion was achieved on a Dionex AS4A (weaker anion exchange column) by using a nitric acid pH gradient eluent (pH 3.3 to 1.3).The entire separation was accomplished in 12 min.The detection limits for the eight arsenic species by IC-ICP-MS were in the range 0.03-1.6 mug l~(-1),based on 3sigma of the blank response (n = 6).The repeatability and day-to-day reproducibility were calculated to be less than 10% (residual standard deviation) for all eight species.The method was validated by analyzing a certified reference material (DORM-2,dogfish muscle) and then successfully applied to several marine samples,e.g.oyster,fish muscle,shrimp and marine algae.The low power microwave digestion was employed for the extraction of arsenic from seafood products.
机译:使用离子色谱(IC)和电感耦合等离子体质谱(ICP-MS)检测对海洋样品中的砷进行形态分析。分离出8种砷,即亚砷酸盐,单甲基砷酸,二甲基砷酸,砷酸盐,砷甜菜碱,四甲基ar用硝酸pH梯度洗脱液(pH 3.3至1.3)在Dionex AS4A(弱阴离子交换柱)上获得氧化,砷胆碱和四甲基ar离子,整个分离过程在12分钟内完成,对8种砷的检出限基于空白响应的3σ(n = 6),通过IC-ICP-MS测定的结果在0.03-1.6杯l〜(-1)范围内。计算得出的重复性和日常重现性均小于10所有八个物种的%(残留标准偏差)。该方法通过分析认证的参考物质(DORM-2,dog鱼肌肉)进行验证,然后成功应用于多种海洋样品,例如牡蛎,鱼肉,虾和海藻。升低功率微波消解用于从海鲜产品中提取砷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号